background image

Vega 56 PC2 

                                                                        Users manual 

 

07/06/1999 

                                                                                   Bausch Datacom 

43

 

Appendix 1 Command Summary 

 
Basic AT Commands 

Command Function 

A/ 

Re-execute the last command. 

Go off-hook and attempt to answer a call 

Dn 

Dial modifier. 

E0 

Turn off command echo 

E1 

Turn on command echo 

H0 

Initiate a hang-up sequence 

H1 

If on-hook, go off-hook and enter command mode 

I0 

Report product code 

I1 

Report pre-computed checksum from ROM 

I2 

Compute checksum and report status 

I3 

Report the firmware version 

I4 

Report defined identifier string 

I5 

Report the country code number 

I6 

Report modem data pump model 

L0 

Set low speaker volume 

L1 

Set low speaker volume 

L2 

Set medium speaker volume  

L3 

Set high speaker volume 

M0 

Turn speaker off 

M1 

Turn speaker on during handshaking and turn speaker off while receiving carrier 

M2 

Turn speaker on during handshaking and while receiving carrier 

M3 

Turn speaker off during dialing and receiving carrier and turn speaker on during 
answering. 

N0 

Turn off Auto mode detection 

N1 

Turn on Auto mode detection 

O0 

Go on-line 

O1 

Go on-line and initiate a retrain sequence 

Force pulse dialing 

Q0 

Allow result codes to DTE 

Q1 

Inhibit result codes to DTE 

Sn 

Select S-Register as default 

Sn? 

Return the value of S-Register n. 

Sn = v 

Set default S-Register to value v. 

S = ? 

Return the value of default S-Register 

Force DTMF dialing 

V0 

Report short from (terse) result codes 

V1 

Report long from  (verbose) result codes. 

W0 

Report DTE speed in Error Correction mode 

Vega 56 PC2 

                                                                        Users manual 

 

07/06/1999 

                                                                                   Bausch Datacom 

44 

W1 

Report line speed, Error Correction protocol and DTE speed 

W2 

Report DCE speed in Error Correction mode 

X0 

Report basic call progress result codes, i.e. OK, CONNECT, RING, NO 
CARRIER (also , for busy, if enabled, and dial tone not detected), NO ANSWER 
and ERROR   

X1 

Report basic call progress result codes and connections speeds (OK, 
CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not 
detected), NO ANSWER, CONNECT, XXXX, and ERROR 

X2 

Report basic call progress result codes and connections speeds, i.e,, OK, 
CONNECT, RING, NO CARRIER (also, for busy, if enabled, and dial tone not 
detected), NO ANSWER, CONNECT, XXXX, and ERROR    

X3 

Report basic call progress result codes and connection rate, i.e., OK, 
CONNECT, RING, NO CARRIER, NO ANSWER, CONNECT, XXXX, BUSY, and 
ERROR 

X4 

Report all call progress result codes and connection rate, i.e., OK, CONNECT, 
RING, NO CARRIER, NO ANSWER, CONNECT XXXX, BUSY, NO DIAL TONE 
and ERROR 

Z0 

Restore stored profile 0 after warm reset 

&C0 

Force RLSD(DCD) active regardless of the carrier state 

&C1 

Allow RLSD(DCD) to follow the carrier state 

&D0 

Interpret DTR ON – to – OFF transition per &Qn 

&D1 

Interpret DTR ON – to – OFF transition per &Qn 

&D2 

Interpret DTR ON - to – OFF transition per &Qn 

&D3 

Interpret DTR ON - to – OFF transition per &Qn  

&F0 

Restore factory configuration 0 

&F1 

Restore factory configuration 1 

&G0 

Disable guard tone 

&G1 

Disable guard tone 

&G2 

Enable 1800 Hz guard tone 

&K0 

Disable DTE/DCE flow control 

&K3 

Enable RTS/CTS DTE/DCE flow control 

&K4 

Enable XON/XOFF DTE/DCE flow control 

&K5 

Enable transparent XON/XOFF flow control 

&K6 

Enable both RTS/CTS and XON/XOFF flow control 

&M0 

Select direct asynchronous mode 

&M1 

Select sync connect with async off-line command mode * 

&M2 

Select sync connect with async off-line command mode and Enable DTR dialing 
of directory zero* 

&M3 

Select sync connect with async off-line command mode and Enable DTR to act 
as Talk/Data switch * 

&P0 

Set 10 pps pulse dial with 39% 61% make/break. (country dependent) 

&P1 

Set 10 pps pulse dial with 33%67% make/break. (country dependent) 

&P2 

Set 20 pps pulse dial with 39% 61% make/break. (country dependent) 

&P3 

Set 20 pps pulse dial with 33% 67% make/break. (country dependent) 

&Q0 

Select direct asynchronous mode 

&Q1 

Select sync connect with async off-line command mode * 

&Q2 

Select sync connect with async off-line command mode and Enable DTR dialing 
of directory zero * 

&Q3 

Select sync connect with async off-line command mode and Enable DTR to act 

Summary of Contents for Vega 56 PC2

Page 1: ...a 56 PC2 Users manual 07 06 1999 Bausch Datacom 1 Bausch Datacom nv sa Vega 56 PC2 Internal ISA Voice Fax Modem Dual Standard V 90 K56Flex Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 2 Users Manual ...

Page 2: ...and Play setting enabled 3 1 1 1 If you have Windows 95 a 3 1 1 2 If you have Windows 95 b or OSR2 3 1 1 3 If you have Windows 98 3 1 2 Internal Modem with Plug and Play setting disabled 3 2 Modem Diagnostic in Windows 95 98 3 4 Installing Modem Drivers in Windows NT4 0 4 Trouble Shooting Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 4 Appendix 1 Command Summary Appendix 2 S Register Summary ...

Page 3: ...tibility 14400 bps send receive G3 compatible Software Compatibility AT Command set compatible Fax Command EIA Class 1 command compatible Error Correction MNP 2 4 and V 42 Data Compression MNP 5 and V 42bis Data Format Serial Binary Asynchronous 7 or 8 data bits odd even or no parity one or two binary serial synchronous stop bit totally 10 bits length DTE to Modem Data Rate MAX 115200bps Operation...

Page 4: ...Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 7 Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 8 ...

Page 5: ...dem should be auto detected by Windows 95 98 Plug and Play 3 1 1 1 If you have Windows 95 a 1 Insert the driver disk supplied with the modem into the Floppy or CD ROM drive and choose Driver from disk provided by hardware manufacturer Then click OK 2 Use Browse to select or fill in the drive letter of the Floppy or CD ROM drive for example A or D and click OK Vega 56 PC2 Users manual 07 06 1999 Ba...

Page 6: ...com 11 3 Select Vega 56 PC2 internal and click OK 3 1 1 2 If you have Windows 95 b or OSR2 1 Click Next Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 12 2 Windows will find the updated driver Vega 56 PC2 internal Then click Finish 3 Click Next ...

Page 7: ...Click Next 2 Click Search for the best driver Then click Next 3 Select Floppy disk drives or CD ROM drive and click Next Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 14 4 Windows will find the Vega 56 PC2 internal Then click Next 5 Click Finish If you install from the floppy select ...

Page 8: ... setting disabled A special procedure must be followed to install a Non Plug and Play internal modem Please check the Hardware installation to setup the jumpers for non Plug and Play If you want to set the modem in COM2 IRQ3 please disable the BIOS of Serial port 2 1 Go to Start Settings Control Panel and double click on the Add New Hardware icon ...

Page 9: ...ded and click Next 4 Click Next Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 18 5 Windows will take several minutes to detect the new hardware When the progress is finished click Details to check the new hardware 6 Check to see if Windows detected the Communication Port Click Finish ...

Page 10: ...anual 07 06 1999 Bausch Datacom 19 Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 20 7 Go to Control Panel and double click on the Modems icon 8 Select Don t detect my modem I will select it from a list and click Next ...

Page 11: ...OM drive for example A or D Then click OK 11 Select Manufacturer Bausch Datacom and Model Vega 56 PC2 internal then click Next If you install from the floppy type A Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 22 12 Select the correct Communication Port and click Next 13 Windows will show Your modem has been set up successfully Click Finish ...

Page 12: ...9 Bausch Datacom 23 Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 24 14 You will see the Vega 56 PC2 internal in the list Click OK When the Installation is complete proceed to setup the dial up networking and communication software ...

Page 13: ...9 Bausch Datacom 25 3 2 Modem Diagnostic in Windows 95 98 1 Go to Start Settings Control Panel and double click on the Modems icon 2 Test the modem by clicking on the Diagnostics tab Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 26 ...

Page 14: ...he COM port for example COM2 or COM3 used by your modem Then click on the More Information button 4 If after communicating with the modem the AT Command screen appears and responds with OK the modem works properly Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 28 ...

Page 15: ...s You have to disable Plug and Play and select a free COM port Please check Hardware installation for the jumpers setup for non Plug and Play If you want to set the modem in COM2 IRQ3 disable the BIOS of Serial port 2 1 Go to Start Settings Control Panel Double click on the Ports icon 2 Click Add Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 30 ...

Page 16: ...r COM 2 for example disable the Serial Port 2 in the BIOS of the motherboard 3 Click on the Restart Now button to restart your Computer 4 Go to Start Settings Control Panel and double click on the Modems icon Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 32 5 Select Don t detect my modem I will select it from a list and click Next 6 Click Have Disk ...

Page 17: ...999 Bausch Datacom 34 7 Use Browse or fill in the drive letter of the floppy or CD ROM drive for example A or D and click OK 8 Select Manufacturer Bausch Datacom and Model Vega 56 PC2 internal Click next 10 Select the correct COM port and click Next If you install from the floppy type A ...

Page 18: ...Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 35 Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 36 6 Click Finish 7 Vega 56 PC2 internal will appear in the list Click Close ...

Page 19: ...ers manual 07 06 1999 Bausch Datacom 37 8 Click Yes to configure the Dial up Networking 14 Click Add 15 Select Vega 56 PC2 internal and click OK 9 Click Configure Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 38 ...

Page 20: ...11 Click on the Network button 12 Select TCP IP and click OK 13 Click Continue Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 40 14 Click Yes to restart your computer Your Vega 56 PC2 modem and the RAS service is now installed In order to make an Internet connection you have to configure dial up networking ...

Page 21: ...ample 8 data bits no parity one stop bit Type AT F ENTER reset original factory default and try to execute the AT commands again Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 42 Modem will not dial out Make sure the phone cable is connected properly to the LINE jack Dial tone can not be detected by the modem Disable X4 Modem will not answer an incoming call Make sure the phone cable is connec...

Page 22: ...ARRIER also for busy if enabled and dial tone not detected NO ANSWER CONNECT XXXX and ERROR X2 Report basic call progress result codes and connections speeds i e OK CONNECT RING NO CARRIER also for busy if enabled and dial tone not detected NO ANSWER CONNECT XXXX and ERROR X3 Report basic call progress result codes and connection rate i e OK CONNECT RING NO CARRIER NO ANSWER CONNECT XXXX BUSY and ...

Page 23: ...nsisting only of numeric digits and upper case letters carrier values for ITU standard modulations take the form letter 1 4digits other letters as needed Defined values are Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 46 B103 For Bell 103 B212 For Bell 212 V21 For V 21 V22 For V 22 V22B For V 22bis V23C For V 23 V32 For V 32 V32B For V 32bis V34 For V 34 K56FLEX For K56flex The modem may als...

Page 24: ...he value range is 75 56000 in the following increments 75 300 600 1200 2400 4800 7200 9600 12000 14400 16800 Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 48 19200 21600 24000 26400 28800 31200 33600 32000 34000 36000 38000 40000 42000 44000 46000 48000 50000 52000 54000 or 56000 as permitted for the associated carrier Default Lowest rate supported by the selected carrier max_rate and max_rx_...

Page 25: ...V 23 b The DTE may disable automode operation see automode c The DTE may constrain the range of modulations available by specifying the lowest and highest rates see min_rate and max_rate below Result Code OK Valid subparameter string ERROR Otherwise Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 50 Error Correction Commands C0 Disable data compression C1 Enable MNP 5 data compression C2 Enable...

Page 26: ...ring Dial H Hang up Vega 56 PC2 Users manual 07 06 1999 Bausch Datacom 52 Appendix 2 S Register Summary S Parameter Summary Register Function Range Units Saved S0 Number of Rings to Automatic Answer 0 255 Rings S1 Ring Counter 0 255 Rings S2 Escape character 0 255 ASCII S3 Line Termination Character 0 127 ASCII S4 Command Line Editing Character 0 127 ASCII S5 Command Line Editing Character 0 255 A...

Page 27: ...age either the long form if verbose or the value only for short form will be generated when that particular value of n shown at the top of the column has been selected by the use of ATXn If the column is blank no message will be generated for that x option A numeral indicates which less explicit message ...

Reviews: