Technical Data
Operating Instructions
Safety I/O Terminals
SI4000 / SO4000
Dokument-Nr.: 5.08009.05
73
D
Cable length between sensor and
terminal (screened line)
max. 100 m
Wire cross section
min. 0.75 mm²
Input process image
6 bytes
Output process image
6 bytes
SO4000 supply voltage
24 V
DC
(-15% / +20%)
Current consumption from I/O-bus
max. 250 mA
Power dissipation of the terminal
typically 2 W
Electrical isolation (between the
channels)
no
Electrical isolation (between the
channels and the I/O bus)
yes
Insulation voltage (between the
channels and the I/O bus, under
common operating conditions)
insulation checked with 500 V
DC
Permissible contamination level
Contamination level 2
(see chapter
Unacceptable operating conditions
Safety terminals must not used under the following
operating conditions:
m
under the influence of ionising radiation
m
in corrosive environments
m
in an environment that leads to unacceptable soil-
ing of the bus terminal
Vibration/shock resistance
conforms to EN 60068-2-6 / EN 60068-2-27
Shocks
15 g with pulse duration 11 ms in all three axes
Protection class
IP20
Permitted operating environment
control cabinet or terminal box with minimum protec-
tion class IP54 according to IEC 60529
Permissable installation position
horizontal
Approvals
CE
WARNING!
The operating conditions specified in the table above may not be exceeded at any
time.
Product name
SO4000
Summary of Contents for SI4000
Page 83: ......