![Baumuller DSD-028 Commissioning And Maintenance Instructions Download Page 19](http://html.mh-extra.com/html/baumuller/dsd-028/dsd-028_commissioning-and-maintenance-instructions_2711393019.webp)
TAM00721
19
DSD-028 / DSD-036 / DSD2-028 / DSD2-036
04/2013
Three-phase-synchronous motor
English
7.2
Resolver – KTY on signal connection
Receptacle:
Size 1 - Straight, Angled or Angled Rotatable
Function
Receptacle
Signal
Contact No.
Schematic
Motor
U
1
Power
8-Pole
Pin Contacts
V
3
W
4
PE
2
Brake
(1)
+
A
-
B
Housing
s.c.
Resolver
COS -
1
Signal
12-Pole
Pin Contacts
SIN -
5
SIN +
6
COS +
8
REF +
10
REF -
12
Temp.-
Sensor
KTY -
7
KTY +
9
Housing
s.c.
Figure 3: Resolver-KTY on signal connection
s.c.: shield connection
(1) brake optional; see nameplate
Schematic: view of the contact side
D
3
1
C
4
B
A
2
3
6
8
4
5
1
2
7
9
12
11
10 P