6.7.2.1 Cabling
h
screen
all
cables connected, so the cables are kept free from perturbing radiation (see
from page 56). You can mount unscreened control cables, if the switch-
ing cabinet has a sufficiently high screen damping (see limit value for radio disturbance
emission according to EMVG for your plant) and if the EMC compatibility inside the
switching cabinet is guaranteed (this you can assume, when you have observed all
configuration instructions given in this manual).
figure 16: Cabling suggestion for BUM64S/A/F
m
If you use Baumüller motor cables you can assume, that the permissible limit values
are not exceeded.
m
The maximum length of the motor cable is limited. The length depends on the cross-
section of the cable
m
The motor cable between converter and motor must consist of one single piece.
Do not interrupt the cable by e.g. terminals, circuit breakers, fuses etc.