D.10 Cable from appliance to motor
1)
EN 60204-1, tab. 5, attachment form C
For UL-conform machines/plants you must use UL-certified cables.
2)
Only for certified cables with this maximum length you can assume, that the EMC regulations are kept.
3)
If you use parallel installed motor lines the maximum length is to be reduced by the factor 1/n.
4)
Mount max. 2 cable lugs per power rail. Do not mount cable lugs onto each other, mount one on each side of the power rail.
Use cable lugs that have a maximum width of 25 mm. Keep in mind that the M10 screw is used for attachment.
D.11 Electrical motor to be connected
1)
depends on the controller
Cross-section
1)
depending on connection
Type of cable
screened, shield’s degree of coverage > 85 %
Maximum length
2)3)
depending on used conductor cross section
up to 4 x 25mm
2
(AWG 10 to 3): 60m
4 x 35mm
2
(AWG 1): 50m
> 4 x 50mm
2
(AWG 1/0): 15m
Cable lug / end sleeve, connection to appliance
4)
cable lug
Motor type
1)
3-phase motor (synchronous, asynchronous)