Installation
Mono Power Unit BUM 62, 63, 64
47
Baumüller Nürnberg GmbH
5.94005.12
y
Sub-unit terminal X99AB
WARNING
The allowed maximum current of 10 A per terminal connection must not be exceeded, otherwise there
is a risk of damaging the devices. With higher current requirements, there must be several, separate
current feeds.
Terminal-No.
Assignment
1, 2
BB ext (PELV)
Relay output: Ready for use of supply converter
24 V, 0.5 A max.
3, 4
Alert (PELV)
Relay output: Alert of supply converter
24 V, 0.5 A max.
5
+ Reset with 24-V signal (PELV)
Input for resetting error messages of the supply converter
(potential-free optocoupler input, 10 ... 25 mA)
6
Ground reset (PELV)
Reference point for resetting error messages of the
supply converter (potential-free optocoupler input)