Operational conditions
Instruction handbook
Safe STO logic
BM5-SSL
Document No. 5.18007.02
Baumüller Nürnberg GmbH
24
4.2
4.2
Operational conditions
4.2.1
Environmental condition
Transport temperature range
- 25 °C to + 70 °C
Transport climate class (K)
EN 60721-3-2
2 K 3
Storage temperature range
- 25 °C to + 55 °C
Storage climate class
EN 60721-3-1
1 K 4
Operational temperature range
min. 5 °C to max. 55 °C
Operational climate class
EN 60721-3-3
3 K 3
Installation altitude
up to 4000 m
Humidity (operating)
EN 60721-3-3
Relative humidity: 5% to 85% non-condensed, and
absolute humidity: 1 g/m
3
to 25 g/m
3
Ionizing and non-ionized radiation
< measurable range
Vibration, shock and continuous shock
EN 61800-5-1, chapter 5.2.6.4 vibration test
Max. 0.5 g when operating
Degree of contamination
EN 61800-5-1, table 6, tab. 2
2
WARNING!
The operating conditions specified in the table above may not be exceeded at any
time.
NOTICE!
Normally only a non-conductive dirt buildup occurs. Any conductive dirt buildup,
whether short-term or permanent, is prohibited and could lead to destruction of the
device. The customer is responsible for destruction resulting from dirt buildup of con-
ductive materials or matter.
4.2.2
EMC characteristics
EMC resistance / emission
In accordance with EN 61800-5-2/DIN EN 61800-3
Summary of Contents for BM5-SSL