Detecting errors in the periphery
Operation Manual
Safety Module for b maXX 5000
BM5-O-SAF-002/3
Document no.: 5.11016.03
Baumüller Nürnberg GmbH
138
19.4
The lists of the diagnosis- and error statuses are listed in
WARNING!
Do not put a defective safety-oriented system back into operation as long as the
cause of the error is unknown or an error has not been detected.
19.4 Detecting errors in the periphery
m
The safe input and output have diagnostic functions in order to detect short circuits and
crossfault on the input and output cables (see
m
Electronic sensors must have an own error detection regarding short circuits on the
output.
CAUTION!
An elimination of errors for short-circuits on line must be made for safe outputs, which
are used separately in order to safely switch-off an actuator. Measures must be taken
in accordance with EN ISO 13849-2.
19.5 Operating states and error messages
Description of operating states in parameter
>
201.12
<
and the possible status- and
error states in
>
201.13
<
>
201.12
<
Description
>
201.13
<
Description
1
Initialization
0
Request synchronization telegram
1
Acknowledgment of synchronization telegram
2
Request of Session ID for FSoE
3
Acknowledgment of Session ID for FSoE
4
Switch on LEDs
5
Switch on waiting time
6
Switch off waiting time
7
Waiting for test manager and online test
8
Waiting for initialization of the GDP protocol