Diagnosis
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
686
3.10
3.10.2 Oscilloscope function
The b maXX
controllers offers an integrated oscilloscope function for quick and easy
commissioning.
Range of oscilloscope function:
3.10.2.1 Parameter overview
Functional block:
FbRsp [101]
Number of channels:
8
Sampling time:
2
n
* 125 µs (n = 0....65535)
Recording:
triggered or not triggered
Triggering:
m
through internal status changes,
m
Size change or
m
external digital or analog inputs
Number of Triggers:
1
Trigger time in relation to
memory depth:
Recording after-running period parameterizable
(which means recording with or without prior
history related to the trigger event)
Trigger sources:
m
Digital signals (selection of relevant bits
through bit masks is possible) e. g.:
n
Status change
n
Error or warning events
n
external digital inputs
m
analog signals
n
Target or actual values
n
Analog inputs
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read o
n
ly
St
o
ra
g
e
DS Supp
ort
Cyclic W
rite
Axis-in
d
ep
end
e
nt
101.1
Status
INT
0
5
0
1:1
X
X
101.2
Command
INT
0
7
0
1:1
X
X
101.3
Channel 0 source
parameter Id
UDINT
0
4294967295
0
ID
1:1
X
101.4
Channel 1 source
parameter Id
UDINT
0
4294967295
0
ID
1:1
X
101.5
Channel 2 source
parameter Id
UDINT
0
4294967295
0
ID
1:1
X
101.6
Channel 3 source
parameter Id
UDINT
0
4294967295
0
ID
1:1
X
101.7
Channel 4 source
parameter Id
UDINT
0
4294967295
0
ID
1:1
X