![Baumuller b maXX BM5800 Parameter Manual Download Page 266](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380266.webp)
Configuration
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
266
3.4
169.2
Status
Status of the Gantry mode:
169.3
Position difference limit
Threshold for the monitoring of the position difference between both Gantry axes.
If the updated position difference is greater than this threshold, bit 4 in parameter
Status is set immediately.
Standardization: 16 bit revolutions, 16 bit angle
One motor revolution corresponds to 65536 increments.
169.4
Position difference time
Time slot for the monitoring of the position difference between both Gantry axes.
If the position difference for this time is greater than the set threshold, bit 5 in parameter
Status is set and depending on the setting in
Mode bit 8 error message
213 "Position difference greater than threshold in Gantry operation" is displayed.
8
1: Report error 213, if position difference for the set time is greater than
the threshold.
9
1: Report error 214, if current difference for the set time is greater than the
threshold.
31 ... 10
Reserved
Bit no.
Meaning
Bit no.
Meaning
3 ... 0
Reserved
4
Position difference is greater than the set threshold
5
Position difference for the set time is greater than the threshold
6
Current difference is greater than the set threshold
7
Current difference for the set time is greater than the threshold
31 ... 8
Reserved