Monitoring functions
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
742
5.2
5.2
Monitoring functions
Monitoring function
Warning/error
Wa
rn
in
g
Error
Adjust
able threshold
Adjust
able reacti
on
Reaction
Phase monitoring
4)
Phase failure
X
X
-
-
IS
Mains failure
X
X
X
-
IS
1)
Overcurrent
Overcurrent motor
-
X
-
-
IS
DC link
DC link overvoltage
-
X
-
-
IS
DC link relative undervoltage
X
-
-
-
-
Overload monitoring
Peak current not possible at this
time
X
-
-
-
-
Heat sink temperature
Temperature > threshold 1
X
-
X
-
-
Temperature > switch-off threshold
-
X
-
-
IS
Temperature of device inte-
rior
Temperature > threshold 1
X
-
X
-
-
Temperature > switch-off threshold
-
X
-
-
IS
Motor temperature
I
2
t threshold exceeded
-
X
-
-
IS
Threshold 1 exceeded
2)
X
-
X
-
-
Threshold 2 exceeded
2)
X
-
X
-
-
Encoder short circuit and/or tem-
perature < -30°C
2)
-
X
-
-
-
Encoder not connected and/or tem-
perature > 250°C
2)
-
X
-
-
-
Maximum temperature exceeded
2)
-
X
X
-
IS
Position controller
Dynamic position error
-
X
X
-
SH
Static position error
-
X
X
-
SH
Controller synchronization
Controller not synchronous with
external signal
X
X
X
X
3)
1)
Pulse inhibit carried out after a specifiable interval
2)
Only if KTY encoder used
3)
Adjustable
4)
Not provided for power modules
IS: pulse inhibit