Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
631
4
m
Bit 8 Status of the speed synchronization on the master axis
The bit will only be operated when the speed synchronization (
Bit 8 = 1) is
switched on.
m
Bit 9 Monitoring the speed synchronicity
This bit indicates leaving the
Synchronization velocity window of the slave ax-
is. Monitoring is activated with completed speed synchronization (
If the speed actual value of the slave axis enters the monitoring window again, Bit 9 will
be deleted.
145.2
Mode
The settings in the mode are transferred to the Operation Enabled status during transfer.
Changes may be made in this status but they will not take effect until blocking and re-re-
lease is completed. Bit 4 is the exception!
Remarks:
m
Bit 3 to 0: Synchronous operation
0010: Virtual master axis in relative synchronized angle
The set value for the slave axis is specified in this mode through Parameter
Virt. lead speed set value. The axis is located in the position control.
Bit no.
Meaning
3 … 0
Type of synchronous operation:
0010: Virtual master axis in relative synchronized angle run
Rest is reserved
4
0: Transparent mode: All changes in transmission factors become effective
immediately
1: Editing mode: The transmission factors may be changed. The transmis-
sion ratio remains unchanged at first. The factors are transferred at the
same time that Bit 4 (1
0) is deleted.
7 … 5
Reserved
8
1: Activate speed synchronization on master axis
9
Speed profile of the ramp generator:
0: Trapezoidal profile
1: S-Curve
11 … 10 Reserved
12
Virtual master axis: Handling of the
Virt. master speed set value
0: Speed set value is routed through ramp generator of the synchronous
operation
1: Speed set value with optional interpolation and without ramp generator
31 … 13 Reserved