Operating Modes
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
604
4.8
4.8.4.1 Parameter overview
Functional block:
FbJogging [119]
4.8.4.2 Description of the Parameters
119.1
Status
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Read only
St
o
ra
g
e
DS Sup
port
Cyclic W
rite
119.1
Status
DWORD 0
0xFFFFFFFF 0
1:1
X
119.2
Mode
UINT
0x0
0xFFFF
0
1:1
X
119.3
Jogging speed
UDINT
0
65535
100
Inc/ms 1:1
X
X
119.4
Jogging acceleration
UDINT
7
65535
200
Inc/
ms²
100:1
X
X
119.5
Jogging deceleration
UDINT
7
65535
200
Inc/
ms²
100:1
X
X
119.6
Jogging maximum jerk
UDINT
7
65535
25
Inc/
ms³
100:1
X
119.7
Output position set value
UDINT
0x0
0xFFFFFFFF 0x0
Inc
1:1
X
119.8
Output speed set value
DINT
-65535
65535
0
Inc/ms 1:1
X
119.9
Output acceleration set value DINT
-65535
65535
0
Inc/
ms²
100:1
X
Bit
Meaning
0
1: Manual drive operation is switched on
3 … 1
Reserved
4
: Speed set value at the output is zero
5
1: Total tipping speed at the input is set to zero
6
1: Total tipping speed > Maximum speed, limited to the lesser value of
Speed limit and
Max speed mech. of the motor.
7
1: Number range limit exceeded
9 … 8
Reserved
10
1: Set Value reached
13 … 11 Reserved
14
1: Drive into negative direction was prevented by limit switch
15
1: Drive into positive direction was prevented by limit switch
31 … 16 Reserved