![Baumuller b maXX BM2500 Operating Manual Download Page 390](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400390.webp)
Management
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
390
4.5
At internal transmission this parameter is displayed for diagnostics.
100.9
Error reaction set value
This error code is sent from the other drive. The receiving drive should execute this reac-
tion, if
bit 0 = 1 and bit 1 = 1.
At external transmission (fieldbus) the parameter must be mapped cyclically so that it ap-
pears as an actual value on the sending drive and as a set value on the receiving drive.
I.e. the control must copy
of drive 1 to
of drive 2.
100.11
Launch application error
The application errors 1 to 5 are set by writing this parameter.
Function
Drive 1
Control
Drive 2
Transmission exter-
nal
= 1
(Drive 1)
(Drive 2)
= 1
Transmission inter-
nal (within a double
axis)
= 3
-
= 3
Value
Error, which is set
0
Noneffective
1
175 - Application error 1
2
176 - Application error 2
3
177 - Application error 3
4
178 - Application error 4
5
179 - Application error 5