Configuration
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
Baumüller Nürnberg GmbH
322
4.4
Example:
The position should be resolved in 0.1° increments and the speed in 0.1°/s increments,
without negation.
P 179.2 = 65536
P 179.3 = 1
P 179.4 = 65536
P 179.5 = 1
P 179.6 = 1
P 179.7 = 1
P 179.8 =
3600
P 179.9 = 1
NOTES!
m
Factor Group total resolutions (position weighting, speed weighting)
16 bit
inc/rev or 16 bit (inc/s)/(rev/s) are permitted only.
m
The accuracy in the controller remains at 16 bit inc/rev even though the Factor
Group position total resolutions were set to > 16 bit inc/rev.
m
Touch probe
The following settings must be set / considered if touch probe objects with a Factor
Group standardization are used:
– Activate channels in parameter
– Map activated channels on the Factor Group objects, DS402 touch probe
– Switch on and select scaling with Factor Group
m
Operating mode "Target Position Setting"
Only the relative target modes 4, 7, 9, 12 (see
) are supported