![Baumuller b maXX BM2500 Operating Manual Download Page 303](http://html.mh-extra.com/html/baumuller/b-maxx-bm2500/b-maxx-bm2500_operating-manual_2711400303.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
303
4
4.4.21.2 Description of the Parameters
165.1
Mode
Mode for the function - configurable status word.
165.2
Configurable status
This parameter shows the status of the parameterized bits of the source parameters. This
parameter shows the results from the logic operations.
The particular status bit is deleted, if the following occurs:
m
The associated channel (source parameter to
>
0.0
<
) is switched off
m
The associated logic operation (
If the function of the logic operations is switched off completely via the
Mode
bit 0 = 0, the state of the completely configurable status is frozen at the shut-off time.
If only the function of all logic operations is switched off via the
Mode bit 1 = 0,
the status of the logic operation outputs (bit no. 16 to 30) is frozen only.
Number
Name
Type
Min
Max
Default Value
Unit
Factor
Rea
d
on
ly
St
o
ra
g
e
DS Su
ppo
rt
Cyc
lic W
rite
165.1
Mode
DWORD 0
0xFFFFFFFF 0
1:1
X
X
165.2
Configurable status
DWORD 0
0xFFFFFFFF 0x0
1:1
X
165.3
Source numbers
RE-
CORD
0
0xFFFFFFFF 0
1:1
X
165.4
Bit mode
RE-
CORD
0
0xFFFF
0
1:1
X
165.5
Logic functions
RE-
CORD
0
6
0
1:1
X
165.6
Latch
DWORD 0
0xFFFFFFFF 0
1:1
X
Bit No.
Meaning
0
Control of the entire function “configurable status word”
0: Configurable Status including the links is switched off; the status of all
is frozen.
1: Activation of “configurable status”.
1
Control of the logic operations
0: All operating functions are switched off; the status of the status bits 16
to 30 of the
is frozen.
1: Activation of the parameterized operations