Description of the Software Modules and Parameters
Parameter manual
b maXX
BM3000
Document no.: 5.12001.07
193
4
137.9
Time first commissioning
Time of the first commissioning of the machine or the encoder
137.10
Time last refresh
Time of the last time update of the encoder. Time stamps are written periodically to the
encoder (not yet implemented).
137.20
Type name
Model name of the encoder.
The following strings are displayed for encoder without communication (without serial
data interface):
m
Resolver
„ Resolver“
m
Square-wave incremental encoder (5 V; TTL): „ Incremental encoder“
m
Sine incremental encoder (~1 Vpp):
„ Sine incr. encoder“
Encoder with communication:
m
Sine-Cosine encoder with SSI interface: „SSI encoder“
m
Sine-Cosine encoder with Hiperface
®
:
The identification is displayed depending on the read type identification:
e.g.:
SRM 60 with identification 27
hex
: „SRM 50/60 / SCM-Kit 101“
SKS 36 with identification 32
hex
: „SKS 36“
unknown identification:
„unknown“
m
Sine-Cosine encoder with EnDat
®
The specified name is composed as follows:
Type of e designation of order + EnDat v EnDat instruction set
e.g.:
Multiturn encoder EQN1325
designation of order 01; EnDat version 02; instruction set 2.2;
= „MultiRotaryED01-2.2“
Singleturn encoder ECN1313
designation of order is not in electronic type plate; EnDat version 02;
instruction set 2.1;
= „SingleRotaryEDxx-2.1“
137.21
Serial number
Serial number of the encoder.