11.1
11.1.5.6 Connection cable add-on modules
IEE
The connection cable is not offered by Baumüller and must be made by the user:
1
Use the following materials:
m
Cable: LiYCY 3 x (2 x 0.14 mm²) + 2 x 0,34 mm² Cu braiding.
m
Sub-D connector: 9-pole, female (IEE side)
m
E.g. Sub-D connector: 26-pole, male (b maXX 5000 side)
m
Cables must be of twisted pair wire (track -0/0, -A/A, -B/B) from incremental encoder
emulation to further master control systems
2
Connect
m
the cable shield with the plug shell of the Sub-D male/Sub-D female connector
m
the 9-pole female connector (IEE side) with the cable
m
e.g. the 26-pole Sub-D male connector (b maXX 5000 side, pin assignment refer to
Connecting cable for sine/square-wave incremental encoder
on page 263) with
the other cable ending.
Figure 116:
Connection cable IEE with b maXX 5500
NOTE!
The connection cable must be made according above mentioned instruction, pin as-
signment IEE refer to
The cable is inoperable with changed assignment of the pins!