Electrical data
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
38
3.4
3.4.2
Single axis modules
BM5807-
S
G
-
22
XXXX-
BM5807-
A
G
-
22
XXXX-
BM5807-
S
G
-
24
XXXX-
BM5807-
A
G
-
24
XXXX-
Input rated power
1)
1.75 kW
2.8 kW
3.5 kW
5 kW
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacity (internal)
235 µF
DC link discharge time (internal DC link capacity)
250 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5) 11)
at 4 kHz
4)
3 A
4.5 A
6 A
8.5 A
Output rated current
(I
AC
RMS)
1) 2) 5) 11)
at 8 kHz
4)
2.1 A
3.15 A
4.2 A
5.9 A
Output rated current
(I
AC
RMS)
1) 2) 5) 11)
at 16 kHz
4)
-
Output peak current
(I
AC
RMS)
1) 5) 6) 11)
at 4 kHz
4)
9 A
18 A
Output peak current
(I
AC
RMS)
1) 5) 6) 11)
at 8 kHz
4)
6.3 A
12.6 A
Output peak current
(I
AC
RMS)
1) 5) 6) 11)
at 16 kHz
4)
-
Short-time operation KB
300 %
200 %
300 %
Max. length of time peak current
6)
Load cycle according EN61800-6
Power loss with regard to power supply
Max. 55 W
Max. 82.5 W Max. 100 W Max. 141 W
Power loss with regard to control voltage supply
7)
Max. 30 W
Current of the integrated brake control
(option)
8)
Max. 2.0 A
12)
Cooling air requirement power heat sink
15 m
3
/h
-
15 m
3
/h
-
Cooling air velocity power heat sink
-
> 5 m/s
-
> 5 m/s
Footnotes refer to