Connection diagrams
Operation manual
b maXX
BM4100 (NWR)
Document no.: 5.04052.09
Baumüller Nürnberg GmbH
76
7.18
Figure 34:
Connections of
b maXX
BM4100 (NWR)
-function modules
BM4-F-UME-01 (slot A)
A: X1-
1
: L1
A: X1-
2
: L2
A: X1-
3
: L3
A: X1-
PE
: PE
BM4-F-SRM-01 (slot B)
B: X1-
1
:
Monitoring signal of main contactor
B: X1-
2:
N
B: X1-
PE
: PE
BM4-F-SRM-02 (slot B)
B: X1-
1
:
Monitoring signal of main contactor
(SELV/PELV)
B: X1-
2:
M24V (SELV/PELV)
BM4-F-SEA-01 (slot C)
C: X1-
1
:
Coil of main contactor
C: X1-
2
:
N
C: X1-
PE
:
PE
BM4-F-SEA-02 (slot C)
C: X1-
1
:
Coil of main contactor
(SELV/PELV)
C: X1-
2:
M24V (SELV/PELV)
BM4-F-DIO-01 (slot D)
D: X1-
1
:Main contactor ON (SELV/PELV)
D: X1-
2
:
D: X1-
3
:
D: X1-
4
:
D: X1-
5
:Ready for pulse enable (SELV/PELV)
D: X1-
6
:Power limit reached (SELV/PELV)
D: X1-
7
:Ready-for-use drive (SELV/PELV)
D: X1-
8
: Ready for main contactor ON
(SELV/PELV)
D: X1-
9
:+24 V (SELV/PELV)
D: X1-
10
:M24 V (SELV/PELV)