Design and Function
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
65
4
LEDs CANopen
®
Type code
BM3200, BM3300
with CANopen
®
:
BM3XXX-XXXX-XXXXX[-X]-
3
XXXX[-S0X]-XX[-XX][-EXX][-#XX]
LEDs without function.
LEDs
POWERLINK
®
Type code
BM3200, BM3300
with POWERLINK
®
BM3XXX-XXXX-XXXXX[-X]-
4
XXXX[-S0X]-XX[-XX][-EXX][-#XX]
Naming on the
front plate
H31 (green)
X3 Link / Act
Off:
No connection
On:
Connection
Blinking:
Data transfer
H32 (yellow)
ERROR
Off:
NMT_CT3, NMT_CT7, NMT_GT2
On:
NMT_CT11, NMT_GT6
Blinking:
Configuration error (e.g. address setting)
H41 (green)
X4 Link / Act
Off:
No connection
On:
Connection
Blinking:
Data transfer
H42 (green)
STATUS
Off:
NMT_GS_OFF, NMT_GS_INITIALISATION,
NMT_CS_NOT_ACTIVE
50 ms off /
50 ms on: NMT_CS_BASIC_ETHERNET
200 ms on /
1 s off:
NMT_CS_PRE_OPERATIONAL_1
2 x 200 ms on /
1 s off:
NMT_CS_PRE_OPERATIONAL_2
3 x 200 ms on /
1 s off:
NMT_CS_READY_TO_OPERATE
On: NMT_CS_OPERATIONAL
200 ms on /
200 ms off: NMT_CS_STOPPED
Meaning
Blinking pattern
Summary of Contents for b maXX 3000
Page 219: ......