Parameter description
Parameter manual
b maXX
®
1000
Document no. 5.07004.03
Baumüller Nürnberg GmbH
82
4.3
When extension card is installed, the number of the multi-function input terminals will in-
crease according to the extension card. The maximum number of the multi-function input
terminals is 12.
Figure 27:
Extension card terminals
P1102
This parameter is used to set the internal terminal action via keypad or communication.
For standard b maXX
®
1000 (without extension card), the multi function input terminals
are MI1 to MI6 as shown in the following.
Figure 28:
Internal terminal 1
P1102
Interner Multi-Funktions-Eingang
0 to 4095
EE
Internal multi function terminal
0
ON
BM_u_InternalMultiFunctionTerminal
1:1