Baumer VEXU Series Quick Start Manual Download Page 2

Data Interface / Digital IOs

USB 3.0 (Micro B)

1 2 3 4 5

6 7 8 9 10

1

VBUS

6

MicB_SSTX-

2

D-

7

Mi

3

D+

8

GND_DRAIN

4

ID

9

MicB_SSRX-

5

GND

10

Mi

Digital-IOs (on camera side)

wire colors of the connecting cable (ordered separately)

1

2

4

3

1

Power IO

brown

3

GND

blue

2

IN1 (Line0)

white

4

OUT1 (Line1)

black

General Description

2

4

3

1

No. Description

No. Description

1

Lens mount (CS-mount)

4

LED

2

Digital IO

3

USB 3.0 port

LED signals

 

LED

Signal

Meaning

LED

green flash

Power on

green

USB 3.0 connection 

red

USB 2.0 connection 

yellow

Readout active

red flash

Update

Installation

Installing the camera:

 

Connect the camera

 

to the USB connection on your PC using an appropriate 

cable. 

 

If required, connect a trigger and / or flash to the digital IOs.

open wire

Installation example

1

 - PCI USB board 

2

 - USB cable

3

 - Cable for trigger and flash

Troubleshooting

1.

 Check camera operation using the LED signals.

→ If LED is red:

 

• Camera is connected to USB 2.0 (settings possible). 

2.

 Check connection using Windows Device Manager:

→ If device is not listed:

 

• Check the host controller power supply.

 

• Check USB 3.0 cable and connection.

→ If device is regularly not listed

 

• Check USB 3.0 driver installation.

Heat Transmission

Caution

Heat can damage the camera. Heat must be dissipated adequately 

to ensure that the temperature does not exceed

 

the values in the 

table below. 

As there are numerous possibilities for installation, Baumer recom-

mends no specific method for proper heat dissipation

, but suggest 

the following principles:

 

operate the cameras only in mounted condition

 

mounting in combination with forced convection may provide 

proper heat dissipation

T

Measurement Point

Maximum Temperature 

Measurement Point (T)

65°C (149°F)