6
Function and definition
6.1
Data sheet
1
Measured with standardized Baumer measuring equipment and objects. Measurement at 90% reflectivity (white)
2
Depending on the size of the measuring field and OBJECT light/dark mode
3
Without filter, without averaging
4
Measured symmetrically around the reference point with 50% of the measuring field
5
Measurement with reduced (90%) measuring range (width)
General data
PosCon OXE7
11111452
OXE7.E25T-11111452
PosCon OXE7
11174280
OXE7.E25T-11174280
PosCon OXE7
11148276
OXE7.E25T-11148276
PosCon OXE7
11177353
OXE7.E25T-11177353
Function
Edge position, center, width,
gap
Edge position, center, width,
gap. For very dark objects
such as tire rubber
Edge position, center, width,
gap. For very precise
measurements
Edge position, center, width,
gap. For very precise
measurements, for very dark
objects
Version
PosCon OXE7
PosCon OXE7
PosCon OXE7
PosCon OXE7
Function: FLEX MOUNT
Yes
Yes
Yes
Yes
Function: MEASURING FIELD
Yes
Yes
Yes
Yes
Measuring range (distance)
150…250 mm
150…250 mm
100…150 mm
100…150 mm
Start of measuring range Sdc
150
150
100
100
End of measuring range Sde
250
250
150
150
Measuring range (width)
75…125 mm
75…125 mm
48…72 mm
48…72 mm
Field of view width right Sdr @
Sde
62.5 mm
62.5 mm
36 mm
36 mm
Field of view width left Sdl @ Sde
-62.5 mm
-62.5 mm
-36 mm
-36 mm
Blind region
0…150 mm
0…150 mm
0…100 mm
0…100 mm
Measuring frequency
125…500 Hz
12
90…250 Hz
159
…625 Hz
111
…370 Hz
Response time
4…16 ms
8…22 ms
3.0
…12.4 ms
8.1
…18.0 ms
Smallest detectable object width
1.5 mm
1.5 mm
0.7 mm
0.7 mm
Smallest detectable gap
2 mm
2.5 mm
1.5 mm
1.5 mm
Smallest detectable step
2 mm
2 mm
0.7 mm
0.7 mm
Resolution
Sdc … Sde
30 … 50 μm
Sdc … Sde
30 … 50 μm
Sdc … Sde
20
Sdc … Sde
20
Repeat accuracy
Sdc … Sde
10
Sdc … Sde
10
Sdc … Sde
10
Sdc … Sde
10
Linearity error
± 80 … ± 120 µm
± 160 … ± 240 µm
± 80 … ± 120 µm
± 160 … ± 240 µm
± 50 … ± 75 µm
± 100
… ± 100 µm
± 50 … ± 75 µm
± 100
… ± 100 µm
Digital output hysteresis
0.5 mm
0.5 mm
0.2 mm
0.2 mm
PRECISION filter values:
Standard
Median Average
Off Off
Median Average
Off Off
Median Average
Off Off
Median Average
Off Off