Seite 10
Design und Spezifikationen können ohne Ankündigung geändert werden
Installationsanleitung 5850-020
www.baumer.com/process
Ex tD A20 IP67 T100, ATEX II 1D - Installation
A Level Switch LFFS-2xx is Ex tD A20 IP67 T100°C, ATEX II 1D
approved for application in hasardous areas in accordance with the
current EU-directives. The product must be installed in accordance
with prevailing guidelines for zone 20 without a barrier.
Ex-data
Supply range
12,5...30 VDC, max 100 mA
Temperature class
T100:
See table 1
External lamp
Level Switch LFFS
+
-
12.5...30 VDC
Ex nA II T5, ATEX II 3G - Installation
Level Switch LFFS
12.5..30 VDC
Remote Lamp
A Level Switch LFFS-3xx is Ex nA II T5, ATEX II 3G approved for
application in hasardous areas in accordance with the current EU-
directives. The product must be installed in accordance with prevailing
guidelines for zone 2 without a barrier.
Ex-data
Supply range
12.5...30 VDC, Max. 0.1A
Temperature class
T1...T5: See table 1
Out