14
Product Specifications
9.
Identification of Firmware version
9.1
Label on Camera ("R2.0" is Firmware 2.0)
•
BGAPI 1.x - Viewer:
•
Camera Information: Hardware Version
(CID Firmware 1.0 starts
with 02 / CID Firmware 2.0 starts with 03 (e.g. CID:020011 - Firmware 1.0)
BGAPI 2.x Camera Explorer:
•
Device Version
: CID Firmware 1.0 starts with 02 / CID
Firmware 2.0 starts with 03 (e.g. CID:030001 - Firmware 2.0)
9.2 Sensor Specifications
Identification of Sensor Version
9.2.1
BGAPI 2.x - Camera Explorer - Device Control
•
DeviceSensorType
(e.g. CMV4000_
V3 - Sensor Version 3)
9.2.2 Quantum Efficiency for Baumer HXG Cameras
The quantum efficiency characteristics of monochrome (also in NIR) and color matrix sen
-
sors for Baumer HXG cameras are displayed in the following graphs. The characteristic
curves for the sensors do not take the characteristics of lenses and light sources without
filters into consideration, but are measured with an AR coated cover glass.
Values relating to the respective technical data sheets of the sensors manufacturer.
350
450
550
650
750
850
950
1050
Wave Length [nm]
Quantum Ef
ficiency [%
]
HXG 20/40 (monochrome)
NIR
350
450
550
650
750
850
950
1050
Wave Length [nm]
Quantum Ef
ficiency [%
]
HXG 20/40 (color)
9.2.3 Shutter
All cameras of the HXG series are equipped with a global shutter.
Pixel
Active Area (Photodiode)
Storage Area
Microlens
Figure 7 ►
Quantum efficiency for
Baumer HXG cameras.
Figure 8 ►
Structure of an imag-
ing sensor with global
shutter