MB068T1 - 11055668
Baumer_POG9-POG9G-T1_DE_EN_202109_MI_11055668 (21A2)
26
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC
5)
(HTL-P, TTL - version R)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
300...5000 (as ordered)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz, ≤300 kHz option
•
Output signals:
K1, K2, K0 + inverted, error output (option EMS)
•
Output stages:
HTL-P (power linedriver), TTL/RS422
(as ordered)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE, UL approval / E217823
9.2
Technical data - mechanical design
•
Size (flange):
ø115 mm
•
Shaft type:
ø11 mm solid shaft
•
Admitted shaft load:
≤250 N axial, ≤350 N radial
•
Flange:
EURO flange B10
•
Protection EN 60529:
IP56
•
Operating speed:
≤12000 rpm (mechanical)
•
Operating torque typ.:
2 Ncm
•
Rotor moment of inertia:
200 gcm
2
•
Materials:
Housing: aluminium die-cast, shaft: stainless steel
•
Operating temperature:
-30…+100 °C
-25…+100 °C (>3072 pulses per revolution)
Restricted in potentially explosive environments, see section 2.
•
Resistance:
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 1 ms
•
Corrosion protection:
IEC 60068-2-52 Salt mist
complies to ambient conditions C4
according to ISO 12944-2
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T135°C Dc (dust)
(only with option ATEX)
•
Connection:
Terminal box (option G: 2x)
•
Weight approx.:
1.4 kg, 2 kg (option G)
5)
The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution