Technical data
8
Technical data
8.1
Technical data - electrical ratings
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE
UL approval / E217823
Option: DNV approval
8.2
Technical data - electrical ratings (square-wave)
•
Voltage supply (Signals):
R
:
4,75...30 VDC
(TTL/RS422)
T
:
5 VDC ±5 %
(TTL/RS422)
H
:
10...30 VDC
(HTL)
U
:
5...30 VDC
(TTL/HTL)
5)
•
Consumption w/o load:
≤70 mA
•
Pulses per revolution:
256...16384 (as ordered)
•
Phase shift:
90° ±10°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Magnetic
•
Output frequency:
≤300 kHz
•
Output signals:
A+, B+, R+, A−, B−, R−
•
Output stages:
HTL
TTL/RS422
(as ordered)
8.3
Technical data - electrical ratings (SinCos)
•
Voltage supply (Signals):
S
:
5 VDC
•
Consumption w/o load:
≤70 mA
•
Sinewave cycles per turn:
256
•
Phase shift:
90° ±5
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Magnetic
•
Output signals:
A+, B+, R+, A−, B−, R−
•
Output stage:
SinCos 1 Vpp
•
Difference of SinCos amplitude:
≤20 mV
•
Harmonics typ.:
-40 dB
•
DC offset:
≤20 mV
5)
At UB = 5 VDC: TTL/RS422; At UB = 10...30 VDC: HTL