Baumer Hübner
Electrical installation
|
6
V1, T1 | HMG10 & HMG10P DeviceNet
Operating Manual
31
6.1.3.2
Mating connector (5-contact, A-coding)
2
1
4
3
5
Ill. 7:
Mating connector (5-contact, A-coded)
Mating connector
Connection
Description
1
DRAIN
Shield connection
2
UB
Operating voltage 10-30 V DC
3
GND
Ground connection for UB
4
CAN_H
CAN Bus Signal (dominant
HIGH)
5
CAN_L
CAN Bus Signal (dominant
LOW)
6.1.4
DeviceNet terminal box
1
2
3
Ill. 8:
DeviceNet Terminal box
1
Setting the terminating resistors
2
Setting the transmission rate
3
Setting the user address
Pin assignment
DRAIN
Shield connection
GND
Ground connection for UB
UB
Operating voltage 10-30 V DC
CAN_H
CAN Bus Signal (dominant HIGH)
CAN_L
CAN Bus Signal (dominant LOW)
INFO
Connectors with the same designation are internally connected and identical in functionality.
These internal terminal connections UB-UB / GND-GND may be loaded with max. 1 A each.