background image

MB175T1 - 11173567

 Baumer_HOGS75K-HOGS75KC_T1_DE_EN_202203_MI_11173567 (22A1)  

2

 

 General notes 

1

1

 

General notes  

1.1

 

Symbol guide:

 

Danger

 

Warnings of possible danger

 

General information for attention

 

Informations to ensure correct device operation

 

i

Information

 

Recommendation for device handling

1.2

 The 

sine encoder HOGS 75 K

 is an 

opto electro nic precision measurement device

 which 

must be handled with care by skilled personnel only.

1.3

 

The expected 

service life

 of the device depends on the 

ball bearings

, which are equipped with 

a permanent lubrication.

1.4

 

The 

storage temperature range

 of the device is between -15 °C and +70 °C. 

 

1.5

 

The 

operating temperature range

 of the device is between -20 °C and +70 °C 

restricted in potentially explosive environments, see section 2, 

measured at the housing.

1.6

 

EU Declaration of Conformity

 meeting to the European Directives.

1.7

 

The device is 

UL approved

 (not applicable for operation in potentially explosive atmospheres).

1.8

 

We grant a 

2-year warranty

 in accordance with the regulations of the ZVEI (Central Association 

of the German Electrical Industry).

1.9

 

Maintenance work

 is not necessary. The device may be only opened as described in this 

instruction. 

Repair work

 that requires opening the device completely must be carried out by the 

manufacturer

. Alterations of the device are not permitted. 

1.10

 

In the event of 

queries

 or 

subsequent deliveries

, the data on the device type label must be 

quoted, especially the type designation and the serial number.

1.11

 

Disposal (environmental protection):

 

Do not dispose of electrical and electronic equipment in household waste. The product 

contains valuable raw materials for recycling. Whenever possible, waste electrical and 

electronic equipment should be disposed locally at the authorized collection point. If 

necessary, Baumer gives customers the opportunity to dispose of Baumer products profession-

ally. For further information see www.baumer.com.

i

Warning!

 

Damaging the seal  

  on the device invalidates warranty. 

Summary of Contents for HOGS 75 K

Page 1: ...MB175T1 11173567 Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 HOGS 75 K HOGS 75 KC Sinus Drehgeber Sine encoder Montage und Betriebsanleitung Mounting and operating instructions...

Page 2: ...ten 9 5 Montage 10 5 1 Schritt 1 10 5 2 Schritt 2 10 5 3 Schritt 3 11 5 4 Schritt 4 12 5 5 Schritt 5 Drehmomentst tze 13 5 6 Hinweis zur Vermeidung von Messfehlern 14 5 7 Schritt 6 15 5 8 Schritt 7 15...

Page 3: ...cope of delivery 9 5 Mounting 10 5 1 Step 1 10 5 2 Step 2 10 5 3 Step 3 11 5 4 Step 4 12 5 5 Step 5 Torque arm 13 5 6 How to prevent measurement errors 14 5 7 Step 6 15 5 8 Step 7 15 5 9 Step 8 16 5 1...

Page 4: ...ach UL gilt nicht f r Einsatz in explosionsgef hrdeten Bereichen 1 8 Wir gew hren 2 Jahre Gew hrleistung im Rahmen der Bedingungen des Zentralverbandes der Elektroindustrie ZVEI 1 9 Wartungsarbeiten s...

Page 5: ...applicable for operation in potentially explosive atmospheres 1 8 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German Electrical Industry 1 9 M...

Page 6: ...079 14 2 3 Eine gegebenenfalls an anderen Stellen aufgef hrte UL Listung gilt nicht f r den Einsatz im Ex Bereich 2 4 Das Ger t darf nur in Betrieb genommen werden wenn die Angaben auf dem Typenschild...

Page 7: ...mm in accordance with EN 60079 14 2 3 An UL listing that may be stated elsewhere is not valid for use in explosive environments 2 4 Operation of the device is only permissible when the details on the...

Page 8: ...Die vorgegebenen Abst nde und oder Winkel unbedingt einhalten 3 4 Zerst rungsgefahr durch mechanischen Schock Starke Ersch tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemal...

Page 9: ...ssential that the specified clearances and or angles are observed 3 4 Risk of destruction due to mechanical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing sy...

Page 10: ...m 6 Erdungsband 195 mm lang 7 Kabelverschraubung M16x1 5 mm f r Kabel 5 9 mm 8 Anschlussklemmen siehe Abschnitt 7 3 1 Housing 2 Cone shaft with spanner flat 17 mm a f 3 Support plate for torque arm 4...

Page 11: ...rnde Mutter M6 ISO 10511 1 K rzbar auf 71 mm 2 K rzbar auf 131 mm 9 Torque arm available as accessory Order number Length L version 11043628 67 70 mm standard 11004078 125 5 mm 1 standard 11002915 440...

Page 12: ...2c Setscrew M6x10 mm ISO 7436 12d Jack screw M8x45 mm ISO 4762 4 3 Zur Demontage erforderlich nicht im Lieferumfang enthalten 4 3 Required for dismounting not included in scope of delivery 4 4 Erforde...

Page 13: ...aumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 10 Montage Mounting 5 5 2 Schritt 2 5 2 Step 2 5 Montage 5 1 Schritt 1 5 Mounting 5 1 Step 1 9 15 14 4 5 Siehe Seite 7 oder 8 See page 7 or 8 13...

Page 14: ...aft Die Antriebswelle sollte einen m glichst kleinen Rundlauffehler aufweisen da dieser zu einem Winkelfehler f hren kann siehe Abschnitt 5 6 Rundlauffehler verursachen Vibrati onen die die Lebensdaue...

Page 15: ..._T1_DE_EN_202203_MI_11173567 22A1 12 Montage Mounting 5 5 4 Schritt 4 5 4 Step 4 Zul Anzugsmoment Max tightening torque Mt 3 4 Nm 12b 12a 11a 11e 11d 11b 11b 21b 11c 11b 9 11c Siehe Seite 7 oder 8 See...

Page 16: ...ge der Drehmomentst tze sollte spielfrei erfolgen Ein Spiel von beispielsweise 0 03 mm entspricht einem Rundlauffehler des Ger tes von 0 06 mm was zu einem gro en Winkelfehler f hren kann siehe Abschn...

Page 17: ...er der Telefon Hotline 49 0 30 69003 111 5 6 How to prevent measurement errors To ensure that the device operates cor rectly it is necessary to mount it accu rately as described in section 5 1 to 5 5...

Page 18: ...7 Step 6 5 8 Step 7 Zur Gew hrleistung der angegebenen Schutzart sind nur geeignete Kabel durchmesser zu verwenden To ensure the specified protection of the device the correct cable diameter must be u...

Page 19: ...eis 5 10 Mounting instruction 5 9 Schritt 8 5 9 Step 8 Siehe Seite 7 See page 7 5 4 TX 10 i Wir empfehlen das Ger t so zu montieren dass der Kabelanschluss keinem direkten Wassereintritt ausgesetzt is...

Page 20: ...T1 11173567 6 Abmessung 73277 73296 6 Dimension 73277 73296 6 Abmessung Dimension Positive Drehrichtung Positive rotating direction Zubeh r Accessory 17 Alle Abmessungen in Millimeter wenn nicht ander...

Page 21: ...reibung der Anschl sse 7 Electrical connection 7 1 Terminal significance UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsanschluss Geh use Earth ground housing K1 A A Ausgangssi...

Page 22: ...werden Kabelabschluss 120 7 4 Sensor cable HEK 8 accessory Baumer H bner sensor cable HEK 8 is recommended As a substitute a shielded twisted pair cable should be used Continuous wiring without any sp...

Page 23: ...3567 Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 20 Demontage Dismounting 8 8 Demontage 8 1 Schritt 1 und 2 8 Dismounting 8 1 Step 1 and 2 5 4 7 10 Siehe Seite 7 oder 8 See page 7 or 8 TX...

Page 24: ...T1_DE_EN_202203_MI_11173567 22A1 MB175T1 11173567 8 Demontage Dismounting 8 2 Schritt 3 8 3 Schritt 4 8 2 Step 3 8 3 Step 4 7 12a 11a 11d 11e 11b 11c 12b 9 Siehe Seite 7 oder 8 See page 7 or 8 6 17 mm...

Page 25: ...Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 22 Demontage Dismounting 8 8 5 Schritt 6 8 5 Step 6 8 4 Schritt 5 8 4 Step 5 8 6 Schritt 7 8 6 Step 7 Siehe Seite 9 See page 9 12c 12c 12d 0 8...

Page 26: ...dbreite 200 kHz 3 dB St rfestigkeit EN 61000 6 2 St raussendung EN 61000 6 3 Zulassungen CE UL Zulassung E256710 9 2 Technische Daten mechanisch Baugr e Flansch 75 mm Wellenart 17 mm Konuswelle 1 10 Z...

Page 27: ...unity EN 61000 6 2 Emitted interference EN 61000 6 3 Approvals CE UL approval E256710 9 2 Technical data mechanical design Size flange 75 mm Shaft type 17 mm cone shaft 1 10 Admitted shaft load 170 N...

Page 28: ...ounting and dismounting kit Order number 11077087 Tool kit Order number 11068265 HENQ 1100 Analyzer for encoders 10 Zubeh r Drehmomentst tze Gr e M6 Bestellnummer siehe Abschnitt 4 2 Sensorkabel f r D...

Page 29: ...MB175T1 11173567 Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 26...

Page 30: ...Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1 MB175T1 11173567...

Page 31: ...MB175T1 11173567 Baumer_HOGS75K HOGS75KC_T1_DE_EN_202203_MI_11173567 22A1...

Page 32: ...6 Baumer H bner GmbH P O Box 12 69 43 10609 Berlin Germany Phone 49 0 30 69003 0 Fax 49 0 30 69003 104 info baumerhuebner com www baumer com motion Originalsprache der Anleitung ist Deutsch Technische...

Reviews: