![Baumer HOG 165 Mounting And Operating Instructions Download Page 31](http://html1.mh-extra.com/html/baumer/hog-165/hog-165_mounting-and-operating-instructions_2711103031.webp)
MB104T1 - 11055715
Baumer_HOG165_T1_DE_EN_202010_MI_11055715 (20A2)
28
Technical data
10
10
Technical data
10.1
Technical data - electrical ratings
•
Voltage supply:
9...30 VDC (HTL)
9...26 VDC (TTL - version R)
5 VDC ±5 % (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
1024...8192 (as ordered)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz
•
Output signals:
K1, K2, K0 + inverted
•
Output stages:
HTL
TTL/RS422
(as ordered)
•
Shaft insulation:
2.8 kV
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approvals:
CE, UL approval / E217823
10.2
Technical data - mechanical design
•
Size (flange):
ø165 mm
•
Shaft type:
ø20...38 mm (through hollow shaft)
•
Admitted shaft load:
≤500 N axial; ≤650 N radial
•
Protection DIN EN 60529:
IP67
•
Operating speed:
≤6000 rpm (mechanical)
•
Operating torque typ.:
15 Ncm
•
Rotor moment of inertia:
4,9 kgcm
2
•
Materials:
Housing: aluminium alloy
Shaft: stainless steel
•
Operating temperature:
-40…+100 °C
Restricted in potentially explosive environments, see section 2.
•
Resistance:
IEC 60068-2-6
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27
Shock 300 g, 6 ms
•
Corrosion protection:
IEC 60068-2-52 Salt mist
complies to ambient conditions CX (C5-M)
according to ISO 12944-2
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
(only with option ATEX)
•
Connection:
Terminal box
•
Weight approx.:
6.1 kg