MB210T1 - 11121634

 Baumer_MHGP100-T1_II_DE-EN (19A2)  

6

 Montage

 / Mounting 

4

 Vorbereitung

 / Preparation 

3

3.1.1

 

Geberrad je nach Version  

3.1.1

 

Encoder wheel depending on version  

3

Geberrad für Klemmringmontage

 

(MHGP 100 B5 

K

)

3.1

Inkrementalspur

3.2

Nullimpulsspur

3.3

Nullimpulsmarkierung

3.4

Klemmring

3.5

Klemmringschraube ISO 4762:

M4x15 mm (øA

H7

 = 25...50 mm)

M4x20 mm (øA

H7

 = 55...65 mm)

M5x20 mm (øA

H7

 = 70...75 mm)

3

Encoder wheel for clamping ring mounting 

(MHGP 100 B5 

K)

3.1

Incremental track

3.2

Zero pulse track

3.3

Zero pulse marker

3.4

Clamping ring

3.5

Clamping ring screw ISO 4762:

M4x15 mm (øA

H7

 = 25...50 mm)

M4x20 mm (øA

H7

 = 55...65 mm)

M5x20 mm (øA

H7

 = 70...75 mm)

3.1

3.2

3.5

3.4

3

3.3

øA

H7

Summary of Contents for HDmag MHGP 100

Page 1: ...sanleitung Mounting and operating instructions MHGP 100 HDmag Lagerloser Drehgeber inkremental Magnetische Abtastung Encoder without bearings incremental Magnetic sensing MB210T1 11121634 Baumer_MHGP1...

Page 2: ...100 B5 K 10 4 2 Montage des Abtastkopfes 11 5 Abmessungen 12 5 1 Schraubmontage und Hei schrumpfmontage MHGP 100 B5 G 12 5 2 Spannsatzmontage MHGP 100 B5 Z 12 5 3 Klemmringmontage MHGP 100 B5 K 13 6...

Page 3: ...nting the sensor head 11 5 Dimensions 12 5 1 Screw mounting and shrink fit mounting MHGP 100 B5 G 12 5 2 Clamping set mounting MHGP 100 B5 Z 12 5 3 Clamping ring mounting MHGP 100 B5 K 13 6 Electrical...

Page 4: ...C bis 85 C am Geh use gemessen 1 5 EU Konformit tserkl rung gem den europ ischen Richtlinien 1 6 Das Ger t ist zugelassen nach UL 1 7 Wir gew hren 2 Jahre Gew hrleistung im Rahmen der Bedingungen des...

Page 5: ...ation of Conformity meeting to the European Directives 1 6 The device is UL approved 1 7 We grant a 2 year warranty in accordance with the regulations of the ZVEI Central Association of the German Ele...

Page 6: ...tterungen z B Hammerschl ge k nnen zur Zerst rung der Abtastung f hren Niemals Gewalt anwenden Bei sachgem er Montage l sst sich alles leichtg ngig zusammenf gen F r die Demontage geeignetes Abziehwer...

Page 7: ...nical shock Violent shocks e g due to hammer impacts can lead to the destruction of the sensing system Never use force Mounting is simple when correct procedure is followed Use suitable puller for dis...

Page 8: ...winde M4 2 Geberrad f r Spannsatzmontage MHGP 100 B5 Z 2 1 Inkrementalspur 2 2 Nullimpulsspur 2 3 Nullimpulsmarkierung 2 4 Spannelement e 2 5 Druckring 2 6 Befestigungsschraube ISO 4762 M4 1 Encoder w...

Page 9: ...alspur 3 2 Nullimpulsspur 3 3 Nullimpulsmarkierung 3 4 Klemmring 3 5 Klemmringschraube ISO 4762 M4x15 mm AH7 25 50 mm M4x20 mm AH7 55 65 mm M5x20 mm AH7 70 75 mm 3 Encoder wheel for clamping ring moun...

Page 10: ...onnector M23 12 pin female CW see section 6 1 4 4 Clearance gage 1 mm 5 Sensorkabel HEK 8 als Zubeh r erh ltlich siehe Abschnitt 6 5 1 6 Befestigungsschraube ISO 4762 M4x35 mm bei Geberrad f r Schraub...

Page 11: ...age siehe 1 in Abschnitt 3 1 1 1 7 Jack screw ISO 4762 M4x20 mm for encoder wheel for screw mounting or shrink fit mounting see 1 in section 3 1 1 3 4 Erforderliches Werkzeug nicht im Lieferumfang ent...

Page 12: ...ing MHGP 100 B5 Z 1 6 Zul Anzugsmoment Max tightening torque Mt 2 3 Nm Zul Anzugsmoment Max tightening torque Mt 2 3 Nm 1 2 2 2 1 1 2 1 2 4 2 5 2 6 1 2 Siehe Seite 5 oder 8 See page 5 or 8 Antriebswel...

Page 13: ...C 4 1 4 Clamping ring mounting MHGP 100 B5 K T 40 C 120 C 1 2 1 1 1 Zul Anzugsmoment Max tightening torque Mt 2 3 Nm 3 4 3 5 3 2 3 1 3 Siehe Seite 6 See page 6 Antriebswelle einfetten Keine Induktions...

Page 14: ...the encoder wheel and the sensor head Check the flush alignment of the encoder wheel and the sensor head on mounting max permissible axial displacement during operation 3 mm 0 9 0 9 1 1 2 mm Luftspal...

Page 15: ...set mounting MHGP 100 B5 Z Nullimpulsmarkierung Zero pulse marker Luftspalt Air gap Nullimpulsmarkierung Zero pulse marker Drehrichtung positiv Positive rotating direction Drehrichtung positiv Positiv...

Page 16: ...nicht anders angegeben All dimensions in millimeters unless otherwise stated H7 5 3 Klemmringmontage MHGP 100 B5 K 5 3 Clamping ring mounting MHGP 100 B5 K Nullimpulsmarkierung Zero pulse marker Dreh...

Page 17: ...th solder contacts assignment see section 6 3 Kabelschirm Cable shield 7 12 mm EMV Ring EMC ring 4 mm 25 mm Code Zur Gew hrleistung der angegebenen Schutzart sind nur geeignete Kabel durchmesser zu ve...

Page 18: ...inal significance UB Betriebsspannung Voltage supply GND 0V Masseanschluss Ground Erdungsanschluss Geh use Earth ground housing A K1 Ausgangssignal Kanal 1 Output signal channel 1 A K1 Ausgangssignal...

Page 19: ...Das Ger t muss immer aus der Folgelek tronik Umrichter Steuerung versorgt werden bzw mindestens eine sehr gute Masseverbindung Hochfrequenz haben die f r ein gleiches Potential zwischen Ger teversorg...

Page 20: ...a shielded twisted pair cable should be used Continuous wiring without any splices or couplings should be used Separate signal cables from power cables Cable terminating resistance 1 3 k for HN UN at...

Page 21: ...r_MHGP100 T1_II_DE EN 19A2 18 Montage Mounting 4 Demontage Dismounting 7 7 Demontage 7 1 Demontage des Abtastkopfes 7 Dismounting 7 1 Dismounting the sensor head 4 4 1 4 5 Siehe Seite 7 oder 8 See pag...

Page 22: ...ing 7 2 Demontage des Geberrades 7 2 1 Schraubmontage MHGP 100 B5 G 7 2 Dismounting the encoder wheel 7 2 1 Screw mounting MHGP 100 B5 G 7 2 2 Spannsatzmontage MHGP 100 B5 Z 7 2 2 Clamping set mountin...

Page 23: ...eite 6 oder 8 See page 6 or 8 7 2 Demontage des Geberrades 7 2 3 Hei schrumpfmontage MHGP 100 B5 G 7 2 4 Klemmringmontage MHGP 100 B5 K 7 2 Dismounting the encoder wheel 7 2 3 Shrink fit mounting MHGP...

Page 24: ...g Phasenverschiebung 90 10 Tastverh ltnis 40 60 Referenzsignal Nullimpuls Breite 90 Abtastprinzip Magnetisch Ausgabefrequenz 2 MHz Ausgangssignale A B R A B R Ausgangsstufen HTL TTL RS422 je nach Best...

Page 25: ...stellung Axiale Toleranz 3 mm Rad Kopf Radiale Toleranz 0 1 2 2 mm Rad Kopf Schutzart DIN EN 60529 IP67 Kopf IP68 Rad Betriebstemperatur 20 85 C Betriebsdrehzahl 8000 U min Werkstoffe Geh use Abtastko...

Page 26: ...er revolution 64 131072 as ordered Phase shift 90 10 Duty cycle 40 60 Reference signal Zero pulse width 90 Sensing method Magnetic Output frequency 2 MHz Output signals A B R A B R Output stages HTL T...

Page 27: ...ordered Axial tolerance 3 mm wheel head Radial tolerance 0 1 2 2 mm wheel head Protection DIN EN 60529 IP67 head IP68 wheel Operating temperature 20 85 C Operating speed 8000 rpm Materials Housing sen...