![Baumer GTR 9 Mounting And Operating Instructions Download Page 20](http://html1.mh-extra.com/html/baumer/gtr-9/gtr-9_mounting-and-operating-instructions_2711005020.webp)
17
Baumer_GTR9_II_DE-EN (19A2)
MB024 - 11055628
9
Technical data
9
Technical data
9.1
Technical data - electrical ratings
•
Reversal tolerance:
≤0.1 %
•
Linearity tolerance:
≤0.15 %
•
Temperature coefficient:
±0.05 %/K (open-circuit),
option: 0.005 %/K
•
Isolation class:
B
•
Calibration tolerance:
±5 %
•
Climatic test:
Humid heat, constant
(IEC 60068-2-3, Ca)
•
Performance:
0.9 W (speed ≥5000 rpm)
•
Armature-circuit time-constant (
τ
A
): <5 µs
•
Open-circuit voltage:
20...60 mV per rpm (as ordered)
•
Interference immunity:
EN 61000-6-2
•
Emitted interference:
EN 61000-6-3
•
Approval:
CE
9.2
Technical data - mechanical design
•
Size (flange):
ø95 mm
•
Shaft type:
ø16 mm (blind hollow shaft)
•
Protection DIN EN 60529:
IP56
•
Torque:
0.35 Ncm
•
Rotor moment of inertia:
1.95 kgcm
2
•
Materials:
Housing: stainless steel / plastic
Shaft: stainless steel
•
Operating temperature:
-30...+130 °C
•
Resistance:
IEC 60068-2-6
Vibration 10 g, 10-2000 Hz
IEC 60068-2-27
Shock 100 g, 6 ms
•
Weight approx.:
1.1 kg
•
Connection:
Connector