EN Assembly instruction and

safety information

(Translation of original instruction)

GCA5 - Analog

Cable transducer with analog interface

   

1.  Identification of notes

Note

Information for intended product use.

    

    

    

2.  Technical data

Voltage supply:

8...30 VDC (voltage output) 

12...30 VDC (current output) 

Consumption w/o load:

Typ. 10 mA (24 VDC, voltage output)

Typ. 30 mA (24 VDC, current output) 

R

ø

ø = 4.6 mm ±0.2 mm

R fix ≥24 mm

R flexible ≥48 mm

7.   Recommended grounding concept

PLC

8.  Terminal assignment

Connector M12 or cable

blue (bu) 

0 V

brown (bn) 

+Vs

black (bk) 

Uout

4 – 

n.c.

5 – 

n.c.

Cable: 3 x 0.5 mm

For customer-specific cable transducers please refer to 

product label and data sheet.

9. Disposal

The cable transducer contains electronic components. 

At its disposal, local environmental guidelines must be 

followed.

6. Assembly

Fit cable transducer on a plain base to avoid excessive 

force on housing. Make sure that drainage holes are free. 

It is recommended to use flat washers.

M4 DIN 912

Screws DIN 125A

Max. 2.5 Nm

10.  General informations

Cable transducer is equipped with rubber wiper at measu-

ring wire inlet. Nevertheless, protect cable transducer and 

measuring wire from water.

Avoid mounting with measuring wire outlet pointing 

upwards to reduce risk of water entry. Freezing water can 

lead to damage. Drainage holes can be opened to allow 

water to drain. Prefer mounting cable transducer with 

drainage holes in low position.

>3°

>3°

<3°

Ensure pulling out of measuring wire in straight direction. 

Maximum misalignment ≤3°. Use pulley to limit misalign-

ment.

Do not loop measuring wire around objects or allow them 

to touch measuring wire. Protect measuring wire from dirt 

and damage.

   

Ensure free rotation of measuring wire fixation to assure 

optimum wire guiding.

Letting snap back of pulled out measuring wire can cause 

injuries and damage of cable transducer.

3.  Intended use

The cable transducer is a precision measuring 

device that is used to record linear positions and 

speeds. It provides measuring values as electronic 

output signals for the subsequently connected 

device. It must not be used for any other purpose. 

Unless this product is specially labeled, it may 

not be used for operation in potentially explosive 

environments. Make sure by appropriate safety 

measures, that in case of error or failure of the 

cable transducer, no danger to persons or damage 

to the system or operating facilities occurs. Do 

not directly connect with on board supply system 

but with a DC/DC converter which is released by 

automotive standardization group.

4.  Personnel qualification

Installation and assembly of this product may be performed 

only by a person qualified in electronics and precision 

mechanics.

5. Maintenance

The cable transducer is maintenance-free and must not 

be opened up nor mechanically or electronically modified. 

Opening up the cable transducer can lead to injury caused 

by the spring.

Summary of Contents for GCA5

Page 1: ...darf nicht geöffnet beziehungsweise mechanisch oder elektrisch ver ändert werden Ein Öffnen des Seilzug Wegsensors kann zu Verletzungen durch die Feder führen 7 Empfohlenes Erdungskonzept PLC 8 Anschlussbelegung Stecker M12 oder Kabel 1 blau bu 0 V 2 braun bn Vs 3 schwarz bk Uout 4 n c 5 n c Kabel 3 x 0 5 mm2 Bei kundenspezifischen Seilzug Wegsensoren überprüfen sie bitte das entsprechende Typensc...

Page 2: ... pointing upwards to reduce risk of water entry Freezing water can lead to damage Drainage holes can be opened to allow water to drain Prefer mounting cable transducer with drainage holes in low position 3 3 3 Ensure pulling out of measuring wire in straight direction Maximum misalignment 3 Use pulley to limit misalign ment Do not loop measuring wire around objects or allow them to touch measuring...

Page 3: ...tien et ne doit pas être ouvert ni mécaniquement ou électriquement modifié En cas d ouverture du capteur de déplacement à câble les ressorts risquent de provoquer des blessures 7 Concept recommandé pour la mise à la terre PLC 8 Configuration de raccordement Connecteur M12 ou câble 1 bleu bu 0 V 2 brun bn Vs 3 noir bk Uout 4 n c 5 n c Câbles 3 x 0 5 mm2 Dans le cas de capteur de déplacement à câble...

Page 4: ...i spostamento a filo non necessita di manuten zione non deve essere aperto e neppure essere sottopos to a modifiche meccaniche o elettriche A causa delle molle si corre il rischio di lesioni se lo si apre 7 Sistema di messa a terra consigliato PLC 8 Configurazione collegamenti Connettore M12 o cavo 1 blu bu 0 V 2 marrone bn Vs 3 nero bk Uout 4 n c 5 n c Cavo 3 x 0 5 mm2 Controllare la relativa tar...

Page 5: ...e desplazamiento por cable puede causar lesiones debido al resorte 7 Sistema de puesta a tierra recomendado PLC 8 Distribución de conexiones Conector M12 o cable 1 azul bu 0 V 2 marrón bn Vs 3 negro bk Uout 4 n c 5 n c Cable 3 x 0 5 mm2 Con sensores de desplazamiento por cable específicos del cliente por favor verifique la placa de identificación y la hoja de datos 9 Eliminación El sensor de despl...

Reviews: