Baumer EFL580 Manual Download Page 10

 

 

Baumer_BiSS-C_MA_EN_V1 00.docx 

10/10 

www.baumer.com 

25.08.2016 

7  Register communication 

 

Writing of the registers calls for utmost care and attention. Writing only of the registers listed in 
this document. Incorrect register writing may cause the encoder outputting incorrect values.  

 

 

Writing only of the command register (0x60).  
Do not write in any other register. 

 

 
Soft preset (0x60 = 0x02)  

Writing 0x02 in register 0x60 will execute preset. (zero set as default).  
Any other preset value requires the corresponding default parameter predefined at Baumer.  

 
The error register 

Register 0x68 is reading the encoder error status. 0x00 mains no error present.  
Bit “0” is the only one to signal error ERR_L (infrared LED current limit error) in the BiSS C frame.  
The warning bit is not used.   
 
Transmission current error: 

 

ERR_L 

0x68; bit 0 

Code 

Function 

no control error present 

amplitude exceeded, or outside control range* 

 

Figure 6 
* EFL580 – outside temperature limit  
 
Error bit transmission is usually inverted (low active).  
 
 

Error Reset

 

The error reset is automatically executed at position data reading.  

 

 

BiSS encoders are programmable to allow for customer-specific parameterization. Should you 
require another different from default, you may approach your Baumer contact for support to 
ensure proper encoder functionality by the correct configuration. We gladly will be of help. 

 
 

Summary of Contents for EFL580

Page 1: ...08 16 174 02 066 1 Subject to modification in technic and design www baumer com Errors and omissions excepted Manual Absolute encoders with BiSS C interface...

Page 2: ...1 Introduction 4 1 1 Product assignment 4 2 Safety and operating instructions 5 3 Introduction 6 4 Functional description 7 4 1 The BiSS Frame 7 4 2 Processing time per request 7 4 3 Bus reset 7 5 Sen...

Page 3: ...tion compiled in the present manual Baumer nor the author will accept any liability for direct or indirect damages resulting from the use of the present information At any time we should be pleased re...

Page 4: ...1 1 Product assignment Product Description GBPAH Multiturn through hollow shaft GBPAS Multiturn blind hollow shaft GBUAH Singleturn through hollow shaft GBUAS Singleturn blind hollow shaft GBPAW Mult...

Page 5: ...upling Hollow shaft Open clamping ring completely before mounting the encoder Foreign objects must be kept at a sufficient distance from the stator coupling The stator coupling is not allowed to have...

Page 6: ...ast and safe exporting of sensor data and simultaneous accessing of the slave registers In the point to point configuration only one device with one slave sensor is operated on the master The BiSS int...

Page 7: ...Master is sent to all slaves via the line MA as an inverse signal level of the BiSS timeout The addressed slave responds with the CDS Control Data Slave bit which is always transmitted in the first b...

Page 8: ...f all data channels The slaves can only correctly signal the BiSS timeout in the BiSS frame if all SLO lines have the signal level 0 at the start of the BiSS timeout The master sends a leading zero be...

Page 9: ...ation of the BiSS timeout in the slave The control frame can be canceled at any time with the transmission of 14 0 bits The start bit of a control frame must be preceded by at least 14 cycles with CDM...

Page 10: ...8 is reading the encoder error status 0x00 mains no error present Bit 0 is the only one to signal error ERR_L infrared LED current limit error in the BiSS C frame The warning bit is not used Transmiss...

Reviews: