Process conditions for ambient temperatures < 50 °C
Type
Process connection
BCID
Process
temperature
continuous
[°C]
Process
pressure
[bar]
Process
tempera-
ture
t < 1 h
[°C]
Process
pressure
t < 1 h
[bar]
T
amb
< 50 °C
T
amb
< 50 °C
LBFS-xx1xx.x
G 1/2 A ISO 228-1 BSC
G07
-40…115
-1…100
135
-1…100
LBFS-xxGxx.x
G 1/2 A ISO 228-1 BSC
with cooling neck
1)
G07
-40…150
-1…100
N/A
N/A
LBFS-xxAxx.x
G 1/2 A DIN 3852-E,
NBR seal
G51
-40…115
-1…100
135
-1…100
LBFS-xxBxx.x
G 1/2 A DIN 3852-E,
FKM (Viton®) seal
G51
-40…115
-1…100
135
-1…100
LBFS-xx4xx.x
G1/2 A hygienic
A03
-40…115
-1…10
135
-1…5
LBFS-xxKxx.x
G1/2 A hygienic, length
82 mm
A03
-40…115
-1…100
135
-1…100
LBFS-xxLx.x
G1/2 A hygienic,
adjustable connection
A03
-40…200
-1…5
N/A
N/A
LBFS-xx5xx.x
G 1/2 A ISO 228-1
for internal installation
T10
-40…85
-1…100
N/A
N/A
LBFS-xx2xx.x
G 3/4 A ISO 228-1
G10
-40…115
-1…100
135
-1…100
LBFS-xx3xx.x
G 1 A ISO 228-1
G11
-40…115
-1…100
135
-1…100
LBFS-xxNxx.x
1/2-14 NPT
N02
-40…115
-1…100
135
-1…100
LBFS-xxMxx.x
1/2-14 NPT with cooling
neck
N02
-40…150
-1…100
N/A
N/A
LBFS-xx6xx.x
3/4-14 NPT
N03
-40…115
-1…100
135
-1…100
LBFS-xx7xx.x
M18x1 ISO 965
M11
-40…115
N/A
N/A
N/A
LBFS-xxExx.x
G 1/2 A DIN 3852-E,
FKM (Viton®) seal,
with cooling neck
G51
-40…150
-1…100
N/A
N/A
1)
Not applicable for mounting with ZPW1-7x1
The temperature specifications apply to a maximum dip depth of the sensor tip into the process area of
20 mm.
14 / 48