![Baumer Camera Link HXC Series User Manual Download Page 17](http://html.mh-extra.com/html/baumer/camera-link-hxc-series/camera-link-hxc-series_user-manual_2710965017.webp)
17
6.5.2 Pin-Assignment Power Supply and Digital IOs
Caution
A power supply with electrical isolation is required for proper operation of the
camera. Otherwise the device may be damaged.
M8 / 3 pins
M8 / 8 pins
1
4
3
8
5
7
3
1
4
2
6
1
(brown)
Power V
CC
1
(white)
Line 9
3
(blue)
GND
2
(brown)
Line 1
4
(black)
not used
3
(green)
Line 0
4
(yellow)
GND
5
(grey)
U
ext
6
(pink)
Line 7
7
(blue)
Line 8
8
(red)
Line 2
Power Supply
Power VCC
9,6 VDC ... 30 VDC
I
Mono8, Camera Link base, dual tap, 40 MHz; 190 mA .. 550
mA
Mono8, Camera Link full, 10 tap, 48 MHz; 200 mA .. 620 mA
Power consumption
approx. 5.5 Watt (with camera factory settings)
6.5.3 LED Signaling
2
1
LED
Signal
Meaning
1
green
Transmitting
red (yellow in both)
Configuration command processing
2
green
Power on
yellow
Readout active