o
The cable can be looped if necessary, but make sure that is not
kinked or trapped when the cooker is in position.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
The mains supply cable should be replaced in accordance with the
following instructions:
o
Switch the appliance off at the control switch.
o
Open the box of the supply board.
o
Unscrew the clamp (A) fixing the cable.
o
Replace the cable with one of the same length and in accordance
with the specification given above.
o
The “green-yellow” earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
o
The “blue” neutral wire must be connected to the terminal
marked with letter (N) - the live wire must be connected to the
terminal marked with letter (L).