background image

19

GB

WARNING! 

DO  NOT  KEEP  PLASTIC  CONTAINERS 

OR ANY FLAMMABLE OBJECTS IN THE APPLIANCE. 
SUCH  OBJECTS  POSE  A  RISK  OF  CATCHING  FIRE 
ONCE THE WARMING DRAWER IS TURNED ON.

WARNING

!  THIS  APPLIANCE  IS  NOT  SUITABLE 

FOR  USE  BY  PEOPLE  (CHILDREN  INCLUDED) 
WITH  PHYSICAL,  SENSORIAL,  AND/OR  MENTAL 
IMPAIRMENTS. PEOPLE WITHOUT THE NECESSARY 
EXPERIENCE OR KNOWLEDGE OF THE APPLIANCE 
MUST  BE  SUPERVISED  BY  A  RESPONSIBLE 
PERSON  FOR  THEIR  OWN  SAFETY.  CHILDREN 
MUST  BE  SUPERVISED  TO  ENSURE  THEY  DO  NOT 
PLAY WITH THE APPLIANCE.

WARNING

:  REMEMBER  THAT  CHILDREN’S  SKIN 

IS  MORE  DELICATE  AND  SENSITIVE  TO  HIGH 
TEMPERATURES.  KEEP  APPLIANCE  AWAY  FROM 
CHILDREN.  APPLIANCE  MAY  OVERHEAT  IF  USED 
INCORRECTLY: RISK OF BURNS

WARNING

:  THE  INSIDE  OF  THE  APPLIANCE  CAN 

REACH  TEMPERATURES  OF  75°C  DEPENDING  ON 
THE  SELECTED  TEMPERATURE  AND  THE  TIME 
OF  OPERATION.  IF  NECESSARY  USE  GLOVES  TO 
REMOVE THINGS FROM THE DRAWER.

WARNING

:  ACCESSIBLE  PARTS  MAY  BECOME  HOT 

DURING  USE.  YOUNG  CHILDREN  SHOULD  BE  KEPT 
AWAY.

THE APPLIANCE MUST NOT BE INSTALLED BEHIND A 
DECORATE DOOR IN ORDER TO

THIS  APPLIANCE  IS  INTENDED  FOR  DOMESTIC 
USE  ONLY!  FOLLOW  THESE  INSTRUCTIONS  TO 
AVOID  DAMAGING  THE  APPLIANCE  OR  CREATING 
DANGEROUS SITUATIONS:

s$ONOTLEANORSITONTHEWARMINGDRAWERWHENOPENED

 

this could  cause  damage  to  the  telescopic  guide.  The 

maximum carrying weight of the warming drawer is 10kg.

CLEANING

:

s

 

.EVER

 

USE

 

A

 

VACUUM

 

CLEANER

 

4HE

 

VACUUM

 

COULD

 

create pressure on the components causing a short 
circuit. The vacuum may also damage the surface and 
the components of the appliance: damages for which the 
manufacturer will not be liable.

s&ORCLEANINGTHEAPPLIANCEWERECOMMENDFOLLOWINGTH
E

 

suggestions listed under “Cleaning and Maintenance” 

of the manual.

REPAIRS

:

s

 

ATTENTION

! Maintenance work and/or repairs must 

be performed exclusively by specialized

 personnel 

Incorrect installation and maintenance can cause 

- The electrical fuse is disconnected.
- The  cord  of  the  appliance  is  disconnected  from  the 

electrical  outlet  –  to  disconnect  the  appliance  from 
the outlet pull the cord away from the outlet, manually 
disconnect  the  cord.  The  manufacturer  will  not  be 
liable for damage caused by a failure to follow current 
regulations  or  the  use  of  non-original  replacement 
parts.

4. INSTRUCTIONS FOR THE CONSUMER

4.0 OPENING OF THE DRAWER

To open the drawer press the front of the drawer

(fig. A)

Grasp the handle 

(fig. B),

 

Pull the drawer

personal injury to the consumer for which the 
manufacturer will not be liable.

ATTENTION

! During the warranty period, the appliance 

may only be serviced by technicians authorized by the 

manufacturer or the warranty will be void.

s

 

ATTENTION

! Before beginning maintenance, 

installation, or repair work disconnect the appliance from 
the electrical outlet.
The appliance is disconnected only if:

AVOID OVERHEATING.

Summary of Contents for ILWD615

Page 1: ...ione WARMING DRAWER GB Installation Use Maintenance TIROIR CHAUFFE VAISSELLE FR Installation Emploi Entretien W RMEFACH DE Installation Gebrauch Wartung CAJ N CALIENTAPLATOS ES Instalaci n Uso Manteni...

Page 2: ......

Page 3: ...BEFORE YOU BEGIN 6 CONTROL PANEL 7 USING YOUR WARMING DRAWER 8 USING YOUR WARMING DRAWER 9 TROUBLESHOOTING 10 APPLIANCE INSTALLATION CONSUMER INSTRUCTIONS Includes recommendations for use description...

Page 4: ...risk for children Your old appliance must also be disposed of properly Important consign the appliance to the proper local organization authorized to collect broken appliances Proper and intelligent d...

Page 5: ...aximum carrying weight of the warming drawer is 10kg CLEANING s EVERUSEAVACUUMCLEANER 4HEVACUUMCOULD create pressure on the components causing a short circuit The vacuum may also damage the surface an...

Page 6: ...under Cleaning and Maintenance Heat the warming drawer for at least two hours Once heated set the temperature to 75 C Be sure that the kitchen is kept well ventilated during the heating period The me...

Page 7: ...umer without the assistance of the Service Department The drawer is not hot enough Make sure that s 4HE APPLIANCE IS TURNED ON s 4HE CORRECT TEMPERATURE HAS BEEN SET s 4HE OPENING OF THE VENTILATION F...

Page 8: ...22 GB 6 0 0 16 21 66 772 1 662 21 2512 WARMING DRAWER DIMENSION DIAGRAM 560 X 595 FOR 480 OVENS...

Page 9: ...23 GB 6 0 0 16 21 66 772 1 662 21 2512 WARMING DRAWER DIMENSION DIAGRAM 560 X 595 FOR 450 OVENS...

Page 10: ...0 554 140 562 145 594 540 22 560 455 540 450 540 20 594 X X DIMENSIONAL DIAGRAM DRAWER 145 BUILT IN 560 X 595 WITH 455 MM WINE CELLAR X OPTIONAL BRACKETS TO ORDER WHEN THE WOODEN STRIP IS COMBINED WIT...

Page 11: ...25 GB 595 560 50 560 510 50 554 140 562 145 594 540 22 454 594 22 494 421 557 516 402 496 DIMENSIONAL DRAWING DRAWER 145 BUILT IN 560 X 595 WITH 454 MM COFFEE MACHINE...

Page 12: ...26 GB 595 560 50 560 510 50 554 140 562 145 594 540 22 451 594 22 DIMENSIONAL DIAGRAM DRAWER 145 BUILT IN 560 X 595 WITH 451 MM TV...

Page 13: ...E TYPES AND MINIMAL DIAMETERS SASO H05RR F 3x0 75 mm H05RR F 3x1 5 mm H05VV F 3x0 75 mm H05VV F 3x1 5 mm H05RN F 3x0 75 mm H05RN F 3x1 5 mm H05V2V2 F 3x0 75 mm H05V2V2 F 3x1 5 mm WARNING Before connec...

Page 14: ...note...

Page 15: ...note...

Page 16: ...Cod 2 002 56 3 2ed...

Reviews: