8
Positioning
o
It is advisable that your appliance is only installed in a location
where the ambient temperature of the room, corresponds with
the climate classification that is stated on the rating plate of your
appliance. Your appliance may not function correctly if the
ambient temperature falls outside of the following ranges.
Climate classification Appropriate ambient temperature
SN
+10 to +32 degrees centigrade
N
+16 to +32 degrees centigrade
ST
+18 to +38 degrees centigrade
T
+18 to +43 degrees centigrade
o
Positioning the appliance requires two people in order to avoid
injuries or damage to the appliance.
o
Your appliance should not be located in direct sunlight or
exposed to continuous heat or extremes of temperature (e.g.
next to a radiator or boiler). If this is not feasible, then you
should install an insulation plate between the appliance and the
adjacent heat source.
o
You should check whether there is an electrical socket available,
which will be accessible after your appliance is installed.
o
Place the appliance flatly and firmly on a solid base. The
appliance is fitted with adjustable feet on the front side, which
should be used to level the appliance.
o
Be sure to leave enough space for the opening of the door, to
avoid damage to the appliance or personal injury.
o
IMPORTANT: The vent at the base of the appliance is for
ventilation. Nothing should be placed in front of this vent;
otherwise your wine cabinet may not operate properly.