
30
Electrical connection
o
Before connecting the appliance, make sure that the
supply voltage marked on the rating plate
corresponds with your mains supply voltage.
o
We recommend that the appliance is connected by a qualified
electrician, who is a member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
o
WARNING: THIS APPLIANCE MUST BE EARTHED.
o
This appliance is supplied with a moulded plug, which must be
connected to an earthed socket.
o
If in future you need to change the fuse in this plug, then a 13
amp ASTA approved (BS 1362) fuse must be used.
o
The socket must still be accessible even when your microwave is
located on the worktop.
o
The wiring in the mains lead is coloured as follows:
Brown
Live
Blue
Neutral
Green and yellow
Earth
o
As the colours of the wires in the appliance’s mains lead may not
correspond with the coloured markings identifying the terminals
in your spur box, please proceed as follows:
The brown wire must be connected to the terminal marked “L”
(live), or coloured red.
The blue wire must be connected to the terminal marked “N”
(neutral), or coloured black.
The green and yellow wire must be connected to the terminal
marked “E” (earth), or by the earth symbol, or coloured green
and yellow.
o
When the connection is completed, no stray strands or cut wire
should be present. The cord clamp must be secured over the
outer sheath.
Summary of Contents for BTM25.5SS
Page 1: ...1 bu BTM25 5SS 25 Litre combination microwave oven with grill...
Page 35: ...35...
Page 36: ...36...