Baumatic BP64S Instructions For The Installation And Use Download Page 9

9

INSTRUCTIONS FOR THE INSTALLER

Electrical connection

The appliance is supplied with a standard 10 

Amp service cord terminated by a 3-pin plug for 

connection to a standard household socket. The 

electrical supply is required to power the electronic 

ignition system.

NOTE: It will be necessary for servicing purposes 

to disconnect the electrical power supply. The 

power point should therefore be accessible after 

the appliance is installed, as specified in the local 

wiring regulations.

TESTING APPLIANCE OPERATION

After installation the installer must fully test the 

appliance and ensure it operates correctly before 

handing it over to the customer.

GAS CONVERSIONS AND ADJUSTMENTS

Data Label

This appliance is suitable for Natural Gas and 

Universal LPG; ensure that the available gas supply 

matches the Data Label.

When converting from Natural Gas to Universal 

LPG ensure that the NG regulator is removed 

and replaced with the Test Point Assembly. An 

AGA Approved gas regulator suitable for a supply 

pressure of 2.75kPa should be part of the gas 

tank supply and the test point pressure should be 

adjusted to 2.75kPa.

Replacing the injectors

If the equipment is adjusted for a type of gas that is 

different from the one available, it is necessary to 

replace the burner injectors.

The choice of the injectors to replace must be 

made according to the table of the “technical 

characteristics” as enclosed.

Act as follows: 

 

– remove the racks and burners. 

 

– by means of a straight spanner L, unscrew 

the injectors U (fig. 7) and substitute it with the 

corresponding one. 

 

– tighten the injectors strongly. 

After changing the injectors, it is necessary to 

eliminate residual natural gas in the system. 

To do this you have to turn to the maximum 

position then press the knob of each burner and 

wait few seconds.

Adjusting the burners

The lowest flame point must always be properly 

adjusted and the flame must remain on even if 

there is an abrupt shift from the maximum to the 

minimum position.

If this is not so, it is necessary to adjust the lowest 

flame point as follows:

 

– start the burner up

 

– turn the tap up to the minimum position (small 

flame)

 

– remove the knob from the tap rod

 

– introduce a flat-tip screwdriver in the hole F of the 

tap (fig. 8) and turn the by-pass screw up to a 

proper adjustment of the lowest flame point.

As regards U-LPG gas burners, the by-pass 

screw must be tightened completely.

MAINTENANCE

Maintenance Schedule

No regular maintenance is required for the 

FRRNWRS

 

except cleaning.

Replacing the power supply cable

If the power supply cable should be replaced, 

it is necessary to use a cable with a section of 

3x0.75mm

2

, type H05VV-F or H05RR-F, complying 

with the regulations in force.

The connection to the terminal board must be 

effected as shown in fig.9 - 9/A:

brown cable L 

 

(

live

)

blue cable N  

 

(neutral)

green-yellow cable    (ground)

Summary of Contents for BP64S

Page 1: ...COD 208398 00 12 06 2012 INSTRUCTIONS FOR THE INSTALLATION AND USE OF BUILT IN 22 723 MODEL BP64S MODEL BP75S MODEL BP95S Baumatic...

Page 2: ...et and program your LED clock and importantly taking care of your appliance when cleaning please call us because we are here to help you It is important that you read through the following use and car...

Page 3: ...upply cord is damaged it must be replaced by a special cord or assembly available from the manufacturer or its service agent Before carrying out the maintenance or cleaning the equipment cut off power...

Page 4: ...etween the minimum position and the closing point The gas supply can be interrupted by turning the knob clockwise up to the closing position If there is no power supply it is possible to light the bur...

Page 5: ...s obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean ignition spark plugs Fl...

Page 6: ...ectrical supply Don t use a steam cleaner for the cleaning the hob It is advisable to clean the appliance when it is cold Enamelled parts The enamelled parts must be washed with a sponge and soapy wat...

Page 7: ...asher A set of hooks is also supplied for mounting the cook top Depending on the type of mounting surface the suitable type of mounting hook is supplied hook A or hook B For the installation proceed a...

Page 8: ...r is placed between the manifold end and the flat face on the elbow The tapered thread connects to the outlet of the regulator and is sealed on the thread using approved thread sealing tape or approve...

Page 9: ...replace must be made according to the table of the technical characteristics as enclosed Act as follows remove the racks and burners by means of a straight spanner L unscrew the injectors U fig 7 and...

Page 10: ...10 1 2 3 4 5 6 8 7 9 9 A F OFF MAXIMUM MINIMUM...

Page 11: ...th of cooktop casing from benchtop surface 44 mm Gas Connection Electrical Supply Cord 280 295 890 510 2 4 1 2 8 3 MODEL BP95S Depth of cooktop casing from benchtop surface 44 mm NG Universal LPG 1 Ra...

Page 12: ...5 2 SEMI RAPID Universal LPG 2 75 65 31 5 6 Natural 1 00 110 Adjust 6 3 3 AUXILIARY Universal LPG 2 75 52 27 3 4 Natural 1 00 80 Adjust 3 4 4 TRIPLE CROWN Universal LPG 2 75 95 60 12 0 Natural 1 00 16...

Page 13: ...E MINI TRIVET The mini trivet included with this cooktop is to be used for cooking vessels of diameter 120mm or smaller Incorrect fitment Correct fitment Examples of positioning of mini trivet MODEL B...

Page 14: ...accessible for the service technician to perform any necessary repair If your appliance is installed in such a way that a service technician is concerned that damage will be caused to the appliance o...

Page 15: ...15...

Page 16: ...Telephone 1800 444 357 Website www thinkappliances com Applico Ltd P O 92900 Onehunga Auckland 1061 New Zealand Website www baumatic co nz United Kingdom Baumatic Ltd Baumatic Buildings 6 Bennet Road...

Reviews: