Baumatic BMEC9GGESS Instruction Manual Download Page 9

GAS CONNECTING

GAS CONNECTING

HOSE

ATTACHMEN

T FOR LIQUID

GAS

HOSE

ATTACHMENT

FOR NATURAL

GAS

WARNING:

 connect the gas to the oven's gas supply line using

the supplied connector (A) (see figure 11)

F

GB

If the connecting tube must be passed behind the appliance,

observe the regulations of the picture 11D

The possible connections are:

WARNINGS

Concerning rubber flexible tubes, we remember you:

1 - to avoid the tube to be narrowed or crushed

2 - do not submit it to traction or torsion efforts

3 - to avoid contact with sharp edges, etc...

4 - to avoid contact with parts reaching temperatures over 70°C

the ambient temperature

5 - to ensure that they can be checked for all their length.

We recommend to check wether the appliance has been foreseen

for the kind of gas distributed.

The appliance must be connected to the gas piping in a workmanlike

way and in conformity with the regulations in force which lay down

the installation of a safety valve at the end of  the piping.

For butane and propane a pressure reducer conforming to the

standards in force may perform this task. The seal gaskets must

be in accordance with rules.

Once the gas appliance has been connected, check the connection

seal by means of soapy water.

Warning: do not use flames to check any gas leakages.

1 )

 by rigid pipe in iron or copper.

Fig. 11B

F

3 )

  by the insertion of a rubber tube in accordance with rules.

   This tube must be connected directly on the push-on connector,

   concerning the gas used, and it must be blocked with a band.

   In the last case, check the tube's printed date of expiry and

     replace it before this date (see fig. 11B).

2 )

 by flexible tube in stainless steel with continuing wall, with

   mechanical connection in accordance with rules (see fig. 11).

Certain types of cookers can be set for sypply both on the right or

lefthand side. In this case it is sufficient to reverse the position of the

cad nipple reducer. At the end make sure than there is no leakage

of gas (fig 11C).

Inlet

Fig. 12A

Stop

Fig. 11C

Fig. 11D

Once the gas appliance has been connected, check the connection

seal by means of soapy water.

Warning: do not use flames to check any gas leakages.

9

Fig. 11

A

Summary of Contents for BMEC9GGESS

Page 1: ...supplying quality products with a high level of customer service For customers outside the U A E please contact your local Baumatic distributor You can find your local distributor on our website at ww...

Page 2: ...wall of the oven In case of careless use in proximity of the oven door hinges there is hurt danger Do not let children sit down or play with the oven door Do not use the drop down door as a stool to...

Page 3: ...out from the pans diameter Use flat bottomed pans only Whenever possible keep a lid on the pan while cooking You will not need as much heat Cook vegetables potatoes etc with as little water as possibl...

Page 4: ...oven door open for at least 1 minute before pressing the knob again Burner with safety device Repeat the above mentioned procedure and press the oven knob at the same time When the burner is on keep t...

Page 5: ......

Page 6: ...n opening fig 5 B when removing the spit wear oven mitts pull out support G For the function of the turnspit turning the knob on the position according to the model or in some models press the marked...

Page 7: ...ork top burners remove them by pulling upwards and soak them for about 10 minutes in hot water with a little detergent After having cleaned and washed them wipe them carefully Make sure that no burner...

Page 8: ...ere must be a similar 100 cm2 opening directly to the outside situated at a height near floor level so that it is not blocked either inside or outside the wall and so as not to cause disturbances to c...

Page 9: ...or butane and propane a pressure reducer conforming to the standards in force may perform this task The seal gaskets must be in accordance with rules Once the gas appliance has been connected check th...

Page 10: ...750 480 167 l h 0 72 Auxiliary 1000 330 95 l h 1 30 Triple crown 3600 1300 343 l h G P L 30 0 85 Rapide 3000 750 219 g h BUTANE 28 0 65 Semi rapide 1750 480 128 g h PROPANE 37 0 50 Auxiliary 1000 330...

Page 11: ...the work top see fig 14 Disassemble the work top by unscrewing the 4 rear screws A see fig 15 REGULATION OF AIR ADJUSTER oven burner To do this Unscrews the screw A in order to rotate the metal ring a...

Page 12: ...conformes la Directive 93 68 CEE Cet appareil doit tre install conformement aux normes en vigueur et utilis uniquement dans des pi ces bien a r es Avant son installation et son utilisation consulter l...

Page 13: ...lement choisi et le tourner dans le sens inverse des aiguilles d une montre jusqu la position de max En maintenant press e la manette on mettra en fonction l allumage lectrique du br leur Dans le cas...

Page 14: ...op rations ci dessus et en m me temps presser sur la manette du four Quand l allumage s est produit maintenir appuy e la manette pendant environ 10 secondes afin que le clapet de s curit entre en fonc...

Page 15: ...iqu par le symbole plac sur le tableau de bord fig 1A ou selon les mod les positionner la manette du commutateur su le function ventilateur fig 5C Utilisation du four gaz ventil L air chauff du br leu...

Page 16: ...bouton Signal Quand le temps choisi sera chu le signal retentira pendant 7 minutes Pour l arr ter appuyer sur le bouton un seul coup Fr quence signal Quand l affichage montre l horaire du jour la fr...

Page 17: ...chets A s assurer qu ils se bloquent dans les illets B de la porte comme le montre la Fig 9C Uniquement dans les cas qui le pr voient enlever la vitre interne de la porte du four voir fig 9A 5 En s ai...

Page 18: ...es sur la plaque signal tique plac e sur l arri re de l appareil Les conditions de r glage sont indiqu es sur l tiquette appliqu e sur l emballage Ne pas utiliser la poign e de la porte du four pour...

Page 19: ...anentes fentes perforation grilles gaines etc destin e l vacuation de l air des cuisines qui doit tre d au moins de 100 cm2 La norme sp cifie que la partie sup rieure de l ouverture permanente utilis...

Page 20: ...ctionner avec un type de gaz diff rent de celui de l alimentation disponible il faut changer les injecteurs r gler le d bit r duit des br leurs et changer l about annel Afin de changer les injecteurs...

Page 21: ...z voir table D Remonter tout en sens inverse en faisant attention placer le br leur de fa on correcte sur sa si ge arri re REGLAGE DEBIT REDUIT ROBINETS DE LA TABLE Afin de r gler le d bit r duit proc...

Page 22: ...fermer le robinet du gaz Le constructeur d cline toute responsabilit quant aux dommages subis par des personnes des animaux ou des biens r sultant de la non observation des normes ci dessus indiqu es...

Page 23: ...A A V A A A T H Z 10...

Page 24: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 11 54 02...

Page 25: ...OK NO F min 100cm2 F A A 8 F F A A A...

Page 26: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 12 10 56 600...

Page 27: ...H05 RR F H05 RR F 2 1 3 4 5 L N A N 6 A A...

Page 28: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 16 15 54 7A 7B 4 7C 0 OFF Fig 7C Fan 1 2 3 4 5 6 7 8 3 2 1 5 4 6 Pos 1 1 2 3 4 5 6 100 150 175 200 225 250 50 100 125 150 175 200 C Fig 7B Fig 7A...

Page 29: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 17 09 50...

Page 30: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 17 14 45...

Page 31: ...537961 Libretto cuc 296 F GAS Page 1 29 12 2008 17 16 41 2004 108 EEC www baumatic mea com 393720 3780 4551 0 971 3953 4551 0 971...

Page 32: ......

Reviews: