26
o
The brass links must be positioned as shown in the photograph
on the previous and once established ALL terminal screws must
be tightened down firmly.
o
You should use a good quality screwdriver to carefully, fully
tighten ALL of the terminal screws.
o
If when the hob is first switched on, only two of the zones
work, you should recheck that the terminal screws are all
fully tightened. This should be done before contacting the
Customer Care Department.
o
IMPORTANT: The appliance must NOT be connected to the
mains supply by means of a 13A plug and socket.
o
The cable can be looped if necessary, but make sure that is not
kinked or trapped when the hob is in position. Care must be
taken to avoid the cable being in contact with hot parts of the
appliance.
Replacing the mains supply cable
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement.
The mains supply cable should be replaced in accordance with the
following instructions:
o
Switch the appliance off at the mains supply.
o
Open the terminal block on the underside of the hob.
o
Unscrew the terminal screws fixing the cable.
o
Replace the cable with one of the same length and in accordance
with the specification given on page 25.
o
The “green-yellow” earth wire must be connected to the terminal
marked
. It must be about 10 mm longer than the live and
neutral wires.
o
The “blue” neutral wire must be connected to the terminal
marked with letter (N) - the live wire must be connected to the
terminal marked with letter (L).