21
o
On the underneath of the hob, adjust the clamps into a position
that is suitable for your worktop. Then fully tighten the screws
(C) to secure the hob into position.
Gas connection
This appliance must be installed by a competent
person in accordance with the current versions of
the following UK (United Kingdom) or ROI (Republic
of Ireland) Regulations and Safety Standards or
their European Norm Replacements.
Important information
o
This hob is supplied to run on natural gas only
and cannot be
used on any other type of gas without modification.
o
Conversion for use on LPG and other gases must only be
undertaken by a qualified person. For information on the use of
other gases, please contact the Baumatic Advice Line.
o
The hob must be installed by a qualified person, in accordance
with the current edition of the Gas Safety (Installation and Use)
(Amendment) Regulations and the relevant building/I.E.E.
Regulations.
o
Failure to install the appliance correctly could invalidate
Baumatic’s guarantee and lead to prosecution under the
regulations quoted above.
o
In the UK, GASSAFE registered installers are authorised to
undertake the installation and service work, in compliance with
the above regulations.
Ventilation requirements
o
The room containing the hob should have an air supply in
accordance with the current edition of BS 5440: Part 2:
o
The room must have opening windows or equivalent; some
rooms may also require a permanent vent.
o
If the room has a volume between 5 and 10m³, it will require an
air vent of 50cm² (effective area). Unless it has a door which
opens directly to the outside.
o
If the room has a volume of less than 5m³, it will require an air
vent of 100cm² (effective area).
Summary of Contents for BHG730SS-AUS
Page 1: ...1 el BHG730SS AUS BHG750SS AUS BHG930SS AUS Gas hobs ...
Page 3: ...3 ...
Page 30: ...30 ...
Page 31: ...31 ...
Page 32: ...32 ...