18
o
Never select a knob position between the maximum and off
position.
o
The symbol on the control panel, next to the control knob will
indicate which gas burner it operates.
Pushbutton ignition (B46.1SS)
o
Press in and turn the appropriate control knob anti-clockwise to
the large flame symbol.
o
Whilst pressing in the control knob, press and hold down the
ignition button, which is located on the control panel.
o
The ignition spark will operate, you should hold down the ignition
button until the flame on the burner has lit.
o
To regulate the flame, you should continue turning the control
knob anti-clockwise until the flame is at a suitable level. The
operating position MUST be at a position between the maximum
and minimum position.
o
To switch the burner off, turn the control knob fully clockwise to
the gas off position.
o
In case of power failure, the burners can be lit by carefully using
a match.
Pushbutton ignition with flame failure safety device
(B46.1TCSS/B60.3SS/BT61.1SS)
The appliance is fitted with a flame failure safety device on each
burner, which is designed to stop the flow of gas to the burner head in
the event of the flame going out.
o
Press in and turn the appropriate control knob anti-clockwise to
the large flame symbol.
o
Whilst pressing in the control knob, press and hold down the
ignition button, which is located on the control panel.
o
You should hold down the ignition button for 20 seconds after
the flame on the burner has lit.
o
After this 20 second interval, turn the control knob to your
required setting between the maximum and minimum setting
symbols.