MB046 - 11055649
Baumer_HOG75K_II_DE-EN (14A1)
24
Technical data
9
9
Technical data
9.1
Technical data - electrical ratings
•
Voltage supply:
9...26 VDC (HTL, TTL - version R)
5 VDC ± 5% (TTL)
•
Consumption w/o load:
≤100 mA
•
Pulses per revolution:
250...2500 (As precised on order)
•
Phase shift:
90° ±20°
•
Duty cycle:
40...60 %
•
Reference signal:
Zero pulse, width 90°
•
Sensing method:
Optical
•
Output frequency:
≤120 kHz
•
Output signals:
K1, K2, K0 + inverted
•
Output stage:
HTL
TTL/RS422
(As precised on order)
•
Interference immunity:
EN 61000-6-2:2005
•
Emitted interference:
EN 61000-6-3:2007/A1:2011
•
Approvals:
CE, RoHS, UL approval / E256710
9.2
Technical data - mechanical design
•
Size (flange):
ø75 mm
•
Shaft type:
ø17 mm (cone shaft 1:10)
•
Shaft loading:
≤80 N axial
≤150 N radial
•
Protection IEC 60529:
IP 56
•
Operating speed:
≤10000 rpm (mechanical)
•
Operating torque:
≤4 Ncm
•
Rotor moment of inertia:
180 gcm
2
•
Materials:
Housing: aluminium die-cast
Shaft: stainless steel
•
Operating temperature:
-30...+85 °C
(restricted in potentially explosive environments, see section 2)
•
Resistance:
IEC 60068-2-6:2007
Vibration 48 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 200 g, 6 ms
•
Explosion protection:
II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIB T85°C Dc (dust)
•
Connection:
Connecting terminal
•
Weight approx.:
860 g