Issue 2: 2016
SERVICE & GUARANTEE
8.2 How to make a Guarantee Claim
On receipt of the goods and order the Company will
examine the goods and determine the nature and
cause of the defect. If the defect is covered by the
guarantee a replacement or repair will be effected at
the Company's expense. If the defect is not covered by
the guarantee the Company will quote the Purchaser
for the replacement or repair, and will not proceed until
written acceptance of such quotation is received.
During the first year of the guarantee the Company will
bear the cost of returning guarantee replacement or
repaired goods to the purchaser's premises in the
country to which the goods were originally delivered.
At the purchaser's request and expense, the Company
will return goods to other countries.
During the second to the fifth year of the guarantee the
return of guarantee replacement or repaired goods
shall be at the Purchaser's expense.
Always adhere to safe local regulatory disposal practise
for alkaline batteries used within the AUDIT Instrument.
Care should be taken that the couplant used is neither
harmful to the operator nor will it attack the probe. For
advice please contact Baugh & Weedon.
Page 18
Issue 2: 2016
OPTIONAL EQUIPMENT
1.3 Optional Equipment
Item
Transducer type 2.5MHz BD52 DT35 5MHz/0.25”
Transducer type 7.5MHz BD17 DT37 7.5MHz/0.87”
Transducer type 5.0MHz BD25 DT39 Hi-Temp
2. TECHNICAL SPECIFICATION
2.1
Thickness Range Interface Echo technique
Minimum 0.63mm Maximum 500.0mm
0.025”
19.0 in
2.2 Accuracy & Calibration
Velocity
Range 1200m/s to 10000ms
0.0492 in/µs to 0.3930in/µs
.
Resolution: 0.01mm. (0.001”
Accuracy:
± 0.01millimeters ±0.001inches
Material dependent
2.3 Power Supply
Source: 2 x LR6( AA) Alkaline Batteries or
rechargeable equivalents
Battery life: 50 hours continuous (alkaline dry batteries)
Auto power off timer: 5 Minutes
.
Page 4
Issue 2: 2016
INTRODUCTION
Before using the equipment, operators should make
themselves fully conversant with the operating
procedures as laid out in this handbook
1.2 Standard Schedule of Equipment
Dimension 121 x 70.3 x 32.3mm
Weight 295g including batteries
The standard equipment package consists of the
following.
Product
AUDIT 207 Thickness Gauge.
0704/A207
Complete with two AA alkaline batteries
•
Plastic Transit/Carrying Case
0704/0175.
•
Probe type 5MHz BD25
DT35 5MHz
•
Operator Handbook.
0704/0201
•
Ultrasonic Coupling Agent
0704/185
Page 3
Issue 2: 2016
SERVICE & GUARANTEE
8. SERVICE & GUARANTEE OF EQUIPMENT
8.1 Guarantee
AUDIT 207 is guaranteed for five (5) years, excluding
batteries and transducers which have been subject to
wear.
Baugh & Weedon ("the company") undertakes to make
good by sending a replacement or, at it's option, by
repairing defects arising from faulty design, material or
workmanship within a five (5) year period from the date
of dispatch.
Your existing consumer rights are not affected by these
guarantees and conditions.
Always adhere to site rules and guidelines concerning
Health & Safety when using the AUDIT 207 Instrument.
Always wear safety equipment appropriate to the area
where the measurement is to be made.
There are no user serviceable parts inside the
instrument case of the AUDIT 207 Service work should
only be carried out by qualified personnel .