TECHNICAL DATA
BG 24 H / 2010
3 - 8
3.6
NOISE EMISSION
1. Inside (cab)
Sound pressure level measurement made in accordance with ISO/DIN 11201
Sound-pressure level in cab
L
PAI
= 76.0 dB(A)
2. Outside
Measurements made in accordance with ISO 4872
Average sound-pressure level L
PA
= 82.0 dB(A)
Sound-power level
L
WA
= 112.0 dB(A)
3.7
TEMPERATURE CONDITIONS
The drilling equipment can be used at temperatures ranging from -20° C to +40° C (-4 to
+104 F).
For use in temperatures outside the specified range, BAUER must be consulted.
3.8
EXPOSURE TO VIBRATIONS
The operator’s exposure to vibration acceleration during operation with this equipment
is less than 0.5 m/s
2
.