Baudcom BD-5800H Operating Manual Download Page 26

 
 

       

1550nm external modulated optical transmitter operating manual

 

 

Website: www.baudcom.com.cn    Tel

+86-21-37709251    Email: [email protected]     

- 25 -

flash red   

Laser    TEC              HIGH                                       

The laser is off 

Verify that the unit is operating 

within the proper temperature 

range (-5

+45

). 

Verify that nothing is 

obstructing airflow through the 

openings in the front and back 

of the unit. 

Recall factory settings by 

pressing the key on the front 

panel (see Section 3). 

If that does not correct the 

problem, contact Customer 

Service. 

OutPutPower    Status    HIGH 

(LOW)                         

The laser is off 

Reboot the equipment. If that 

does not correct the problem, 

contact Customer Service. 

None 

None 

The optical output 

power is lower 

than the nominal 

value   

Check the fiber connector. 

Follow the connector cleaning 

procedure (see Section 6.1). 

If that does not correct the 

problem, contact Customer 

Service. 

6.3 Disclaimer 

We reserve the right to change any products described herein at any time, and without 
prior  notice.  We  assume  no  responsibility  or  liability  arising  from  the  use  of  the 
products described herein, except as expressly agreed to in writing by us. The use and 
purchase of this product does not convey a license under any patent rights, copyrights, 
trademark  rights,  or  any  intellectual  property  rights  of  us.  Nothing  hereunder 
constitutes  a  representation  or  warranty  that  using  any  products  in  the  manner 
described herein will not infringe any patents of third parties. 

 

Summary of Contents for BD-5800H

Page 1: ...Shanghai Baudcom Communication Device Co LTD Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn Model BD 5800H 1550nm External Modulated Optical Transmitter Operating Manual...

Page 2: ...1 220V Power Module 8 3 3 2 48V Power Module 8 3 4 Menu Operation 9 3 4 1 Main Menu 9 3 4 2 Display Menu 10 3 4 3 Set Menu 11 3 4 4 Alarm Menu 12 3 4 5 AGC Mode 12 3 4 6 MGC Mode 12 3 4 7 Frequency Ad...

Page 3: ...om cn Tel 86 21 37709251 Email info baudcom com cn 2 5 5 WEB Network Management 21 6 Maintenance and Troubleshooting 23 6 1 Cleaning Fiber Optic Connectors 23 6 1 1 Cleaning Patch Cord or Pigtail Fibe...

Page 4: ...do in the event of problems 1 2 Product Description This optical transmitter is a 1550nm DFB laser external modulated transmitter It is specially developed for the CATV signal that satisfies HFC netw...

Page 5: ...es The threshold value can be set up to 19dBm The optical modulator has a two way optical signal output Parts of that signal are routed to an InGaAs photodiode This detection of the optical signal has...

Page 6: ...justment Range GHz 50GHz Optical Power dBm 2 5 2 7 2 8 2 9 2 10 SBS Threshold Value dBm 13 19 Continuously adjustable Laser Linewidth MHz 0 3 2 2 Model Test Indicators Test Model C42 D59 D84 D84 Chann...

Page 7: ...z input noise current density EDFA with 5dB noise figure RF input level at 80 dB V TV channel 2 4 Technical Data Sheet Item Unit Technical Parameters RF range MHz 47 1003 RF flatness dB 0 75 RF return...

Page 8: ...UP key 8 DOWN key 9 Enter key 10 RF input port or on the rear panel optional 11 20dB RF input test port 3 1 1 Indicator Description Power indicator One power supply LED yellow Two power supplies LED...

Page 9: ...input port or on the front panel optional 5 RS232 interface 6 LAN interface 7 Optical output interface A or on the front panel optional 8 Optical output interface B or on the front panel optional 3 3...

Page 10: ...www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn 9 3 4 Menu Operation 3 4 1 Main Menu Displayed parameters Comments Boot display 1 Disp Parameters Menu one Display parameters 2 Set Par...

Page 11: ...12V Read 12V monitor voltage RF CSO CSO monitor voltage 12V Read 12V monitor voltage RF Source The current RF signal source LASER Laser status Laser Cooling Cooling current SBS Module Temp SBS module...

Page 12: ...and AGC two modes selectable Set AGC Set MGC Set RF adjusted value Adjustable range 0 15dB with MGC mode Adjustable range 3 3dB with AGC mode Set SBS Suppression Set SBS value Range 13 19dBm 0 5dB st...

Page 13: ...nd also the standard operation The optical transmitter will automatically adjust to the optimal gain while the input level is in the working range see the technical data sheet And the specified OMI rm...

Page 14: ...r unit inspect the shipping container and equipment for damage Save the shipping material for future use If the container or the equipment is damaged notify both the freight carrier and us CAUTION To...

Page 15: ...t F connector type according to the ordering information then screw on the matched RF cable 4 3 3 Connecting the Optical Fiber Cables It has two output optical connectors DANGER The fiber carries invi...

Page 16: ...Ethernet port on the rear panel 4 3 5 Connecting Power The is available in an AC power model or DC power model After mounting the equipment in a rack follow the power connection procedure below for th...

Page 17: ...definitions as follow 1 No Connect 2 TX 3 RX 4 No Connect 5 GND 6 No Connect 7 No Connect 8 No Connect 9 No Connect The serial communication uses the standard NRZ form 1 starts bit 8 data bits 1 stop...

Page 18: ...e of serial port As follows Change the serial port configuration to 38400 baud rate 8 data bits no parity bit 1 stop bit no data flow control press the OK button you have set up the Windows serial por...

Page 19: ...rating manual Website www baudcom com cn Tel 86 21 37709251 Email info baudcom com cn 18 Then turn on the power you will see the page as follows Enter the password to enter the configuration interface...

Page 20: ...ing as follows help This command shows current application program version program name and the internal commands list of the system as follows You can also use the help command to show help informati...

Page 21: ...s community This command configures the read only group name and read write group name Group name is the concept of SNMP agreement like the password Use the command community ro to configure the read...

Page 22: ...upgrades Management Information Base MIB is the organized hierarchical information set Use SNMP to visit these MIB They are composed of manageable information and identified by the object identifier S...

Page 23: ...ace Click Set Paraments to enter Set Paraments interface as follows The Item and Items columns list the parameters that can be changed the Current column lists the present parameter values the New col...

Page 24: ...formance and in some cases distortion performance We recommend that you clean all mating fiber connectors before connecting them to an optical transmitter In addition if you suspect that the optical c...

Page 25: ...sted in Table 6 1 Table 6 1 Troubleshooting Solutions Indicator status Alarm menu content Fault phenomenon Solution Power indicator is yellow Power Invalid LEFT RIGHT The left right power is break dow...

Page 26: ...Customer Service None None The optical output power is lower than the nominal value Check the fiber connector Follow the connector cleaning procedure see Section 6 1 If that does not correct the prob...

Reviews: